Description

Thickness Gauge with a measuring range of 0 ... 2000 µm / Micro-USB /
statistics function / limit value alarm function / temperature and moisture measurement / V-groove 
Software for transferring the measured values 

The Thickness Gauge has a measuring range of 0 ... 2000 µm. The Thickness Gauge can measure the coating thickness on ferrous (Fe) and non-ferrous (NFe) metals. For a better analysis of the measurements, the coating thickness gauge has a measuring function based on the SSPC standards. With this function, the corrosion protection of a coating can be checked with the Thickness Gauge.

The Group function stores the measured values directly on the Thickness Gauge. A memory of 50 groups with 50 measurements each is available on the Thickness Gauge. In each group, statistics are created for all measured values from the Thickness Gauge. All measurement data and statistics can be recalled after a measurement run on the Thickness Gauge.

For further analysis of the measured values, the Thickness Gauge can be connected to a PC. The Thickness Gauge has a micro-USB interface for this purpose. The software can be used to transfer the measurement data from the Thickness Gauge to a PC. In addition, it is possible to carry out live measurements with the Thickness Gauge using the software. For further processing of the measured values from the Thickness Gauge, they can be exported in CSV and XLS format via the software. 

In addition to the coating thickness measurement, the Thickness Gauge can measure the temperature and humidity of the environment. Thus, the Thickness Gauge can be used to find out whether the climatic conditions are right to carry out further processing on the coating. 

With the V-groove, the coating thickness of, for example, pipes can also be determined with the Thickness Gauge. 

Highlights

- Measuring range 0 ... 2000 µm
- with SSPC measuring function 
- Individually adjustable limit value alarms  
- Data memory with up to 2500 measured values
- temperature and humidity measuring function 


Specification

  
Measurement on ferrous metal (Fe)
Measuring range0 ... 2000 µm
Resolution0.1 µm @ 0.0 ... 99.9 µm
 1 µm @ 100 ... 2000 µm
Accuracy±(2 % ±2 µm of Mw.)
Repeatability±(1 % ±1 µm of Mw.)
Smallest radius of curvature1.5 mm
Smallest measuring areaØ7 mm
Smallest layer thickness0.5 mm
  
Measurement on non-ferrous metal (NFe)
Measuring range0 ... 2000 µm
Resolution0.1 µm @ 0.0 ... 99.9 µm
 1 µm @ 100 ... 2000 µm
Accuracy±(2 % ±2 µm of Mw.)
Repeatability±(1 % ±1 µm of Mw.)
Smallest radius of curvature3 mm
Smallest measuring area Ø5 mm
Smallest layer thickness0.3 mm
  
Temperature 
Measuring range0 ... 50 °C / 32 ... 122 °F
Resolution0.1 °C / °F
Accuracy±1.2 °C / ±2.2°F
  
Humidity 
Measuring range0 ... 100 % r. h.
Resolution0.1 % r. h.
Accuracy±3.2 % r. h. @ 20.0 ... 70.0 % r. h.
 ±4.0 % r. h. @ 0.0 ... 19.9 % r. h.
 ±4.0 % r. h. @ 70.1 ... 100.0 % r. h.
  
Further specifications 
Base material for measurements Ferrous (Fe) and non-ferrous (NFe) metals
Display2.4 " LC display
Automatic display orientation0, 90, 180 and 270 °, can be switched off
 (only measuring window)
Statistic functionsaverage, highest, lowest and SDEV measured value
Measuring modesdirect, groups, SSPC
Unitsµm, mm, mils, inch
Power supply2 x 1.5 V AA batteries
InterfaceMicro-USB (for data transfer only)
Alarmsignal tone and / or LED signal light in case of
 Exceeding of the adjustable upper and lower alarm limit
Switch-offOff, 30 seconds, 1 minute, 5 minutes
Menu languagesEnglish, German, French, Spanish,
 Italian, Portuguese, Chinese, Japanese
Operating conditions0 ... 50 °C, 20 ... 90 % r.h., non-condensing
Storage conditions-10 ... +60 °C, 20 ... 90 % r.h., non-condensing
Dimensions 35 x 64 x 137 mm
Weight 175 g
  

Delivery Scope

1 x Thickness Gauge PCE-CT 29-ICA
1 x set of standard foils
1 x carrying case,
1 x calibration plates (Fe and NFe)
1 x mass data storage
2 x 1.5 V AA battery, 
1 x instruction manual
1 x ISO Calibration Certificate