Data Logger with USB Interface PCE-428-EKIT
US$ 5,386.00
ex. VAT, ex. delivery costs

The data logger with USB interface PCE-428-EKIT, from the field of environmental measurement technology, is an optimal sound level meter for measurements at workplaces, construction sites, in traffic, airports, etc. The data logger with USB interface is a class 2 device and is equipped with an octave band frequency filter. Optionally, the data logger with USB interface PCE-428-EKIT can be upgraded with a 1/3 octave band filter. The additional kit for outdoor sound measurement makes it possible to measure outdoor noise with a SPL meter over a long period of time, even in the rain.

 

- Accuracy class 2 
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- incl. outdoor noise level meter kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise

Power Analyzer PCE-830-2
US$ 3,564.00
ex. VAT, ex. delivery costs

The PCE-830-2 Power Analyzer is used for measuring one to three phases of electrical quantities for alternating current (AC). This Power Analyzer also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.


  • PCE-830 + PCE-6802 amp clamp (1000 A)
  • Electrical conductor pick-up: 55 mm / 2.1 in diameter
  • Range selection: manual (10 A, 100 A, 1000 A)
  • Clamp dimensions: 244 mm x 97 mm x 46 mm / 9.6 in x 3.7 in x 1.8 in
  • Sampling rate: 2 sec.
  • Memory size: 512 kB (max. 52,000 values (single phase)

Power Meter PCE-830-2
US$ 3,564.00
ex. VAT, ex. delivery costs

The PCE-830-2 Power Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This Power Meter also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.


  • PCE-830 + PCE-6802 amp clamp (1000 A)
  • Electrical conductor pick-up: 55 mm / 2.1 in diameter
  • Range selection: manual (10 A, 100 A, 1000 A)
  • Clamp dimensions: 244 mm x 97 mm x 46 mm / 9.6 in x 3.7 in x 1.8 in
  • Sampling rate: 2 sec.
  • Memory size: 512 kB (max. 52,000 values (single phase)

Clamp Meter PCE-830-2
US$ 3,564.00
ex. VAT, ex. delivery costs

The PCE-830-2 Clamp Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This Clamp Meter also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.


  • PCE-830 + PCE-6802 amp clamp (1000 A)
  • Electrical conductor pick-up: 55 mm / 2.1 in diameter
  • Range selection: manual (10 A, 100 A, 1000 A)
  • Clamp dimensions: 244 mm x 97 mm x 46 mm / 9.6 in x 3.7 in x 1.8 in
  • Sampling rate: 2 sec.
  • Memory size: 512 kB (max. 52,000 values (single phase)

Clamp on Tester PCE-830-2
US$ 3,564.00
ex. VAT, ex. delivery costs

The PCE-830-2 Clamp on Tester is used for measuring one to three phases of electrical quantities for alternating current (AC). This Clamp on Tester also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.


  • PCE-830 + PCE-6802 amp clamp (1000 A)
  • Electrical conductor pick-up: 55 mm / 2.1 in diameter
  • Range selection: manual (10 A, 100 A, 1000 A)
  • Clamp dimensions: 244 mm x 97 mm x 46 mm / 9.6 in x 3.7 in x 1.8 in
  • Sampling rate: 2 sec.
  • Memory size: 512 kB (max. 52,000 values (single phase)

Data Logger PCE-830-2
US$ 3,564.00
ex. VAT, ex. delivery costs

The PCE-830-2 Data Logger is used for measuring one to three phases of electrical quantities for alternating current (AC). This Data Logger also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.


  • PCE-830 + PCE-6802 amp clamp (1000 A)
  • Electrical conductor pick-up: 55 mm / 2.1 in diameter
  • Range selection: manual (10 A, 100 A, 1000 A)
  • Clamp dimensions: 244 mm x 97 mm x 46 mm / 9.6 in x 3.7 in x 1.8 in
  • Sampling rate: 2 sec.
  • Memory size: 512 kB (max. 52,000 values (single phase)

HVAC Meter PCE-830-2
US$ 3,564.00
ex. VAT, ex. delivery costs

The PCE-830-2 HVAC Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This HVAC Meter also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.


  • PCE-830 + PCE-6802 amp clamp (1000 A)
  • Electrical conductor pick-up: 55 mm / 2.1 in diameter
  • Range selection: manual (10 A, 100 A, 1000 A)
  • Clamp dimensions: 244 mm x 97 mm x 46 mm / 9.6 in x 3.7 in x 1.8 in
  • Sampling rate: 2 sec.
  • Memory size: 512 kB (max. 52,000 values (single phase)

Clamp Meter PCE-PA 8300-2
US$ 4,105.00
ex. VAT, ex. delivery costs

The easy-to-use PCE-PA 8300 Clamp Meter is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. The PCE-PA 8300 is a 3-phase power analyzer that features:


  • Voltage measurement range of 10 V … 600 V AC
  • Current measurement range of (Set 2) 30 A … 3000 A AC
  • Performance measurement range of 0 kW … 9.999 MW (VA/VAR)
  • Simultaneous display of harmonics and waveform
  • Graphic Phasor diagram
  • Captures transients including dip, swell, and outage

Clamp-On Tester PCE-PA 8300-2
US$ 4,105.00
ex. VAT, ex. delivery costs

The easy-to-use PCE-PA 8300 Clamp-On Tester is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. The PCE-PA 8300 is a 3-phase power analyzer that features:


  • Voltage measurement range of 10 V … 600 V AC
  • Current measurement range of (Set 2) 30 A … 3000 A AC
  • Performance measurement range of 0 kW … 9.999 MW (VA/VAR)
  • Simultaneous display of harmonics and waveform
  • Graphic Phasor diagram
  • Captures transients including dip, swell, and outage

Power Analyzer PCE-PA 8300-2
US$ 4,105.00
ex. VAT, ex. delivery costs

The easy-to-use PCE-PA 8300 Three Phase Power Data Logger is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. The PCE-PA 8300 is a 3-phase power analyzer that features:


  • Voltage measurement range of 10 V … 600 V AC
  • Current measurement range of (Set 2) 30 A … 3000 A AC
  • Performance measurement range of 0 kW … 9.999 MW (VA/VAR)
  • Simultaneous display of harmonics and waveform
  • Graphic Phasor diagram
  • Captures transients including dip, swell, and outage

Power Meter PCE-PA 8300-2
US$ 4,105.00
ex. VAT, ex. delivery costs

The easy-to-use PCE-PA 8300 Power Meter is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. The PCE-PA 8300 is a 3-phase power analyzer that features:


  • Voltage measurement range of 10 V … 600 V AC
  • Current measurement range of (Set 2) 30 A … 3000 A AC
  • Performance measurement range of 0 kW … 9.999 MW (VA/VAR)
  • Simultaneous display of harmonics and waveform
  • Graphic Phasor diagram
  • Captures transients including dip, swell, and outage

Electrical Tester PCE-830-2
US$ 3,564.00
ex. VAT, ex. delivery costs

The PCE-830-2 Electrical Tester is used for measuring one to three phases of electrical quantities for alternating current (AC). This Electrical Tester also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.


  • PCE-830 + PCE-6802 amp clamp (1000 A)
  • Electrical conductor pick-up: 55 mm / 2.1 in diameter
  • Range selection: manual (10 A, 100 A, 1000 A)
  • Clamp dimensions: 244 mm x 97 mm x 46 mm / 9.6 in x 3.7 in x 1.8 in
  • Sampling rate: 2 sec.
  • Memory size: 512 kB (max. 52,000 values (single phase)

Data Logger PCE-PA 8300-2
US$ 4,105.00
ex. VAT, ex. delivery costs

The easy-to-use PCE-PA 8300 Data Logger is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. The PCE-PA 8300 is a 3-phase power analyzer that features:


  • Voltage measurement range of 10 V … 600 V AC
  • Current measurement range of (Set 2) 30 A … 3000 A AC
  • Performance measurement range of 0 kW … 9.999 MW (VA/VAR)
  • Simultaneous display of harmonics and waveform
  • Graphic Phasor diagram
  • Captures transients including dip, swell, and outage

Portable Power Analyzer PCE-PA 8300-2
US$ 4,105.00
ex. VAT, ex. delivery costs

The easy-to-use PCE-PA 8300 Three Phase Power Data Logger is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. The PCE-PA 8300 is a 3-phase Portable Power Analyzer that features:


  • Voltage measurement range of 10 V … 600 V AC
  • Current measurement range of (Set 2) 30 A … 3000 A AC
  • Performance measurement range of 0 kW … 9.999 MW (VA/VAR)
  • Simultaneous display of harmonics and waveform
  • Graphic Phasor diagram
  • Captures transients including dip, swell, and outage

Electrical Tester PCE-PA 8300-2
US$ 4,105.00
ex. VAT, ex. delivery costs

The easy-to-use PCE-PA 8300 Electrical Tester is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. The PCE-PA 8300 is a 3-phase power analyzer that features:


  • Voltage measurement range of 10 V … 600 V AC
  • Current measurement range of (Set 2) 30 A … 3000 A AC
  • Performance measurement range of 0 kW … 9.999 MW (VA/VAR)
  • Simultaneous display of harmonics and waveform
  • Graphic Phasor diagram
  • Captures transients including dip, swell, and outage

Current Clamp PCE-830-2
US$ 3,564.00
ex. VAT, ex. delivery costs

The PCE-830-2 Current Clamp is used for measuring one to three phases of electrical quantities for alternating current (AC). This Current Clamp also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.


  • PCE-830 + PCE-6802 amp clamp (1000 A)
  • Electrical conductor pick-up: 55 mm / 2.1 in diameter
  • Range selection: manual (10 A, 100 A, 1000 A)
  • Clamp dimensions: 244 mm x 97 mm x 46 mm / 9.6 in x 3.7 in x 1.8 in
  • Sampling rate: 2 sec.
  • Memory size: 512 kB (max. 52,000 values (single phase)

Current Clamp PCE-PA 8300-2
US$ 4,105.00
ex. VAT, ex. delivery costs

The easy-to-use PCE-PA 8300 Current Clamp is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. The PCE-PA 8300 is a 3-phase power analyzer that features:


  • Voltage measurement range of 10 V … 600 V AC
  • Current measurement range of (Set 2) 30 A … 3000 A AC
  • Performance measurement range of 0 kW … 9.999 MW (VA/VAR)
  • Simultaneous display of harmonics and waveform
  • Graphic Phasor diagram
  • Captures transients including dip, swell, and outage

HVAC Meter PCE-PA 8300-2
US$ 4,105.00
ex. VAT, ex. delivery costs

The easy-to-use PCE-PA 8300 HVAC Meter is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. The PCE-PA 8300 is a 3-phase power analyzer that features:


  • Voltage measurement range of 10 V … 600 V AC
  • Current measurement range of (Set 2) 30 A … 3000 A AC
  • Performance measurement range of 0 kW … 9.999 MW (VA/VAR)
  • Simultaneous display of harmonics and waveform
  • Graphic Phasor diagram
  • Captures transients including dip, swell, and outage