Description

Car measuring device with Bluetooth 4.0 interface / Measuring range 0 ... 1500 V AC/DC /
Expandable with additional flexible current clamp for measurements up to 3000 A AC /
Inrush current measurement / VFD function / Optionally with ISO calibration certificate

The car measuring device is the ideal measuring device for measuring voltages up to 1500 V AC/DC and currents up to 1000 A AC/DC. The current measurement with the clamp meter is inductive. To do this, the supply line is placed in the clamp meter. This has the particular advantage that the current can be measured during operation. This means that the clamp meter is used, for example, for maintenance work on a photovoltaic system. Photovoltaic systems consist of many different solar cells that are connected in series with one another. Here, the current clamps can be used to measure the individual currents of individual rows in order to limit possible errors.

In addition to normal voltage and current measurements, the car measuring device can also measure the inrush current. Inrush currents are currents that are particularly high when the device is switched on. These currents arise when motors start up for ventilation systems, for example, or when stadium lighting is switched on. This measurement with the clamp meter is particularly important for dimensioning the supply line and fuses. Frequency converters are converters that output the voltage on the primary side with a changed frequency and amplitude on the secondary side. With the clamp meter and the VFD measurement function, measurements can be carried out up to a frequency of 45 Hz ... 1 kHz.

The car measuring device also has a Bluetooth 4.0 interface. With this interface on the clamp meter, a connection to an Android and iOS device can be established. With the free “Meterbox Pro” app, the values ​​measured by the clamp meter can be displayed and saved for later analysis.

With the data logging function, the car measuring device can save all measured values ​​at any set interval. After a measurement, the values ​​can be graphically displayed using the clamp meter. Each individual measuring point can also be read individually from the clamp meter. The storage capacity of the clamp meter has a size of 16 groups and a total storage capacity of 100,000 measured values. With the clamp meter, the measured value is saved with the date and time.

The car measuring device can be expanded with an optional current clamp. The additional current clamp to the clamp meter is flexible and can therefore be adapted to the measuring task. With the extended clamp-on ammeter, current measurements of up to 3000 A AC can be carried out. The flexible current clamp is connected to the voltage input of the clamp meter. The current clamp converts the voltage value into a usable current value and shows it on the display.

Because of its many different functions and the high measuring range, the car measuring device is used, for example, for checking photovoltaic systems, hydroelectric power plants, wind power plants or for installing immovable electrical machines. The clamp meter can optionally be equipped with an ISO calibration certificate.

Highlights

- Free app for Android and iOS
- Measuring range 0 ... 1500 V AC/DC
- Data logging for up to 100,000 measured values
- Inrush current measurement
- Additionally with LowZ voltage measurement
- 2.36" TFT display
- With voltage and temperature measurement
- Optionally with calibration certificate

Specification

DC voltage  
Measuring range ±600.0 mV
Resolution 0.1 mV
Accuracy ±(0.8 % of measured value + 8 digits)
Measuring range ±6.000 V
Resolution 0.001 V
Accuracy ±(0.5 % of measured value + 5 digits)
Measuring range ±60.00 V
Resolution 0.01 V
Accuracy ±(0.5 % of measured value + 5 digits)
Measuring range ± 600.0 V
Resolution 0.1 V
Accuracy ±(0.8 % of measured value + 5 digits)
Measuring range ±1500 V
Resolution 1 V
Accuracy ±(0.8 % of measured value + 5 digits)
   
Input impedance: >10 MΩ; Overvoltage protection: 1500 VDC / 1000 VAC rms
   
AC voltage  
Measuring range 0.000 ... 6.000 V
Resolution 0.001 V
Accuracy 50 ... 60 Hz: ±(1.2 % of measured value + 5 digits)
  61 ... 1 kHz: ±(2.5 % of measured value + 5 digits)
Measuring range 0.00 ... 60.00 V
Resolution 0.01 V
Accuracy 50 ... 60 Hz: ±(1.2 % of measured value + 5 digits)
  61 ... 1 kHz: ±(2.5 % of measured value + 5 digits)
Measuring range 0.0 ... 600.0 V
Resolution 0.1 V
Accuracy 50 ... 60 Hz: ±(1.2 % of measured value + 5 digits)
  61 ... 1 kHz: ±(2.5 % of measured value + 5 digits)
Measuring range 0 ... 1500 V
Resolution 1 V
Accuracy 50 ... 60 Hz: ±(1.2 % of measured value + 5 digits)
  61 ... 1 kHz: ±(2.5 % of measured value + 5 digits)
   
The accuracy relates to 10 ... 100% of the respective measuring range
and a sine wave input impedance: >9 MΩ;
Overvoltage protection: 1000 V DC/AC RMS
The accuracy of the "PEAK" function is: ±10 % of measured value
The response time of the "PEAK" function is: 1 ms
   
AC voltage with low input impedance (LowZ)
Measuring range 0.000 ... 6.000 V
Resolution 0.001 V
Accuracy ±(3.0 % of measured value + 40 digits)
Measuring range 0.00 ... 60.00 V
Resolution 0.01 V
Accuracy ±(3.0 % of measured value + 40 digits)
Measuring range 0.0 ... 300.0 V
Resolution 0.1 V
Accuracy ±(3.0 % of measured value + 40 digits)
   
Input impedance: 300 kΩ; Overvoltage protection: 1000 VDC / VAC RMS
The accuracy relates to 10 ... 100% of the respective measuring range and a sine wave
   
DC and AC voltage (50 ... 1 kHz)
Measuring range 0.000 ... 6.000 V
Resolution 0.001 V
Accuracy ±(2.5 % of measured value + 40 digits)
Measuring range 0.00 ... 60.00 V
Resolution 0.01 V
Accuracy ±(2.5 % of measured value + 40 digits)
Measuring range 0.0 ... 600.0 V
Resolution 0.1 V
Accuracy ±(2.5 % of measured value + 40 digits)
Measuring range 0 ... 1000 V
Resolution 1 V
Accuracy ±(2.5 % of measured value + 40 digits)
   
Input impedance: 300 kΩ; Overvoltage protection: 1000 VDC / VAC RMS
   
DC and AC voltage with low input impedance (LowZ)
Measuring range 0.000 ... 6.000 V
Resolution 0.001 V
Accuracy ±(3.5 % of measured value + 40 digits)
Measuring range 0.00 ... 60.00 V
Resolution 0.01 V
Accuracy ±(3.5 % of measured value + 40 digits)
Measuring range 0.0 ... 300.0 V
Resolution 0.1 V
Accuracy ±(3.5 % of measured value + 40 digits)
   
Input impedance: 300 kΩ; Overvoltage protection: 1000 VDC / VAC RMS
   
Non-Contacting Voltage Verification (NCV)
Detection range 100 ... 1000 AC/DC
Direct current  
Measuring range ±60.00 A
Resolution 0.01 A
Accuracy ±(3.0 % of measured value + 8 digits)
Measuring range ±600.0 A
Resolution 0.1 A
Accuracy ±(3.0 % of measured value + 8 digits)
Measuring range ±1000 A
Resolution 1 A
Accuracy ±(3.0 % of measured value + 8 digits)
Overload protection: 1000 A AC/DC  
   
Alternating current (50 ... 60 Hz)  
Measuring range 0.00 ... 60.00 A
Resolution 0.01 A
Accuracy ±(2.5 % of measured value + 5 digits)
Measuring range 0.0 ... 600.0 A
Resolution 0.1 A
Accuracy ±(2.5 % of measured value + 5 digits)
Measuring range 0 ... 1000 A
Resolution 1 A
Accuracy ±(2.5 % of measured value + 5 digits)
   
Overload protection: 1000 A AC/DC
The accuracy relates to 10 ... 100 %
of the respective measuring range and a sine wave
The inrush current measurement is for reference only
   
AC current measurement with flexible clamp meter (50 ... 400 Hz)
Measuring range 0.00 ... 30.00 A
Resolution 0.01 A
Accuracy ±(3.0 % of measured value + 5 digits)
Measuring range 0.0 ... 300.0 A
Resolution 0.1 A
Accuracy ±(3.0 % of measured value + 5 digits)
Measuring range 0 ... 3000 A
Resolution 1 A
Accuracy ±(3.0 % of measured value + 5 digits)
   
Overload protection: 1000 A AC/DC
The accuracy relates to 10 ... 100% of the respective measuring range and a sine wave
   
Resistance and continuity measurement
Measuring range 0.0 ... 600.0 Ω
Resolution 0.1 Ω
Accuracy ±(1.0 % of measured value + 10 digits)
Measuring range 0.000 ... 6.000 kΩ
Resolution 0.001 kΩ
Accuracy ±(0.8 % of measured value + 5 digits)
Measuring range 0.00 ... 60.00 kΩ
Resolution 0.01 kΩ
Accuracy ±(0.8 % of measured value + 5 digits)
Measuring range 0.0 ... 600.0 kΩ
Resolution 0.1 kΩ
Accuracy ±(0.8 % of measured value + 5 digits)
Measuring range 0.000 ... 6.000 MΩ
Resolution 0.001 MΩ
Accuracy ±(0.8 % of measured value + 5 digits)
Measuring range 0.00 ... 60.00 MΩ
Resolution 0.01 MΩ
Accuracy ±(2.5 % of measured value + 10 digits)
   
Continuity test acoustic signal at: <50 Ω
Overvoltage protection: 1000 V AC/DC
   
Frequency measurement  
Measuring range 0.00 ... 60.00 Hz
Resolution 0.01 Hz
Accuracy ±(0.2 % of measured value + 5 digits)
Measuring range 0.0 ... 600.0 Hz
Resolution 0.1 Hz
Accuracy ±(0.2 % of measured value + 5 digits)
Measuring range 0.000 ... 6.000 kHz
Resolution 0.001 kHz
Accuracy ±(0.2 % of measured value + 5 digits)
Measuring range 0.00 ... 60.00 kHz
Resolution 0.01 kHz
Accuracy ±(0.2 % of measured value + 5 digits)
Measuring range 0.0 ... 600.0 kHz
Resolution 0.1 kHz
Accuracy ±(0.2 % of measured value + 5 digits)
Measuring range 0.000 ... 6.000 MHz
Resolution 0.001 MHz
Accuracy ±(0.2 % of measured value + 5 digits)
   
Overvoltage protection: 1000 V AC/DC
Sensitivity:
>2 Vrms with a duty cycle between 20 ... 80 % and a frequency of <100 kHz
>5 Vrms with a duty cycle between 20 ... 80 % and a frequency of >100 kHz
   
Duty cycle  
Measuring range 10.0 ... 90.0 %
Resolution 0.1 %
Accuracy ±(1.2 % of measured value + 8 digits)
   
Frequency range: 40 ... 10 kHz; Pulse amplitude
±5 V with a duration between 100 µs ... 100 mS
   
Capacity  
Measuring range 0.00 ... 60.00 nF
Resolution 0.01 nF
Accuracy ±(3.0 % of measured value + 20 digits)
Measuring range 0.0 ... 600.0 nF
Resolution 0.1 nF
Accuracy ±(3.0 % of measured value + 8 digits)
Measuring range 0.000 ... 6.000 µF
Resolution 0.001 µF
Accuracy ±(3.0 % of measured value + 8 digits)
Measuring range 0.00 ... 60.00 µF
Resolution 0.01 µF
Accuracy ±(3.0 % of measured value + 8 digits)
Measuring range 0.0 ... 600.0 nF
Resolution 0.1 nF
Accuracy ±(3.0 % of measured value + 8 digits)
Measuring range 0 ... 6000 µF
Resolution 1 µF
Accuracy ±(3.5 % of measured value + 20 digits)
Measuring range 0.00 ... 60.00 mF
Resolution 0.01 mF
Accuracy for reference only
Measuring range 0.0 ... 600.0 mF
Resolution 0.1 mF
Accuracy for reference only
   
Overvoltage protection: 1000 A AC/DC
 
Temperature measurement thermocouple Type K (connection)
Measuring range -40.0 ... 600.0 °C
Resolution 0.1 °C
Accuracy ±(1.5 % of measured value + 3 °C)
Measuring range 600 ... 1000 °C
Resolution 1 °C
Accuracy ±(1.5 % of measured value + 3 °C)
Measuring range -40.0 ... 600.0 °F
Resolution 0.1 °F
Accuracy ±(1.5 % of measured value + 5.4 °F)
Measuring range 600 ... 1800 °F
Resolution 1 °F
Accuracy ±(1.5 % of measured value + 5.4 °F)
Measuring range 245.0 ... 600.0 K
Resolution 0.1 K
Accuracy ±(1.5 % of measured value + 3 K)
Measuring range 600 ... 1273 K
Resolution 1 K
Accuracy ±(1.5 % of measured value + 3 K)
   
Overvoltage protection: 1000 A AC/DC
   
Diode test  
Test current <1.5 mA
Maximum voltage 3.3 VDC
   
Further specifications  
Storage space 16 groups with a total storage space
  of 100,000 measured values
Clamp diameter horizontal 38 mm / 1.49"
Clamp diameter vertical 63 mm / 2.48"
Clamp opening 45 mm / 1.77"
Protection class IP65
Interface Bluetooth 4.0
Pollution degree 2
Insulation categories CAT IV 600 V, CAT III 1000 V, CAT II 1500 V
Maximum working height 2000 m / 6562 ft
Power supply battery 7.4 V, 1200 mAh Li-ion battery
Power supply charger      Primary: 100 ... 240 V AC, 50 ... 60 Hz
  Secondary: 12 V DC, 2 A
Plug connection charger Europa, USA, England, China
Battery status display available
Automatic switch-off switched off, 15, 30 or 60 minutes
Display 2.36" TFT
Display frequency 3 Hz
Reference conditions 18 ... 28 °C, 64 ... 82 °F; <80 % RH,
  non-condensing
Dimensions 275 x 100 x 45 mm / 10.8 x 3.9 x 1.7"
Weight 481 g / 16.9 oz

Delivery Scope

1 x Car Measuring Device PCE-CTI 10
1 x Thermocouple Type-K with adapter
1 x Pair of measuring leads
1 x Carrying case
1 x Battery charging station
1 x Rechargeable battery
1 x Instruction manual