Triple Plus + BASE Gas Detector
Clear and unambiguous, simple to customize, durable and easy to maintain
Triple Plus+ is the latest generation of the respected "Triple" family of toxic, oxygen and flammable gas detectors. With over 90,000 units sold to oil and gas, chemical, utility and manufacturing companies worldwide, their combination of ruggedness, reliability, ease of use and sensor flexibility has set the standard for multigas portables.
Today's TriplePlus+ builds on this pedigree by inclusion of unique LIBRA lithium-ion battery technology and the option of infrared (IR) sensors for the measurement of flammable hydrocarbons or carbon dioxide.
Intrinsically safe, the Triple Plus+ provides enhanced features for safety and detector fleet managers including selection of flammable gas correction factors (so one unit can be used in several locations across a site) and annotation of the data file with user names and site names selected from pre-configured files in the unit.
* Call to order or see accessories tab. Must specify sensors (see chart for details) and choose with / without internal pump. Charger and software sold separately.
Alarms: Piezo-electric tone 85 dB at 1 m / 3.28', Confidence blip (adjustable), Distinctive double blip for low battery with user accept, Gas hazard: Vivid flashing red, LED instrument is working: Slow flashing green, LED low battery: Distinctive double flash of green LED
Display: 2 lines of 24 characters, dot matrix high contrast LCD with backlight operating for 30 minutes; Values and units for up to 4 gases displayed simultaneously at current, TWA or peak levels; Low battery, pump failure, real time and elapsed time; Calibration and configuration data also displayed
Data logging: Adjustable sample rate, 100 hours at 1 minute sample rate (maximum 6000 data points per channel), logging of events, user and site
Battery: Rechargeable Li-ion battery pack
Standard instrument battery life: >12 hours
Pumped instrument battery life: >10 hours
Expected sensor life: Flammable: 5 years (Triple Plus+)
IR: 5 years (Triple Plus+ IR)
Toxic: 3 years
Oxygen: 2 years
Typical response times: Methane 20s (Triple Plus+) IR 20s (Triple Plus+IR), Oxygen 10s, typical Toxic Gas 20s
Sampling: Optional internal electric pump with on/off button
Operating temperature: -20°C to +50°C / -4°F to 122°F)
Humidity: 20 to 90% RH non-condensing
Ingress protection: IP65
Approvals:
-Europe: ATEX II 2G: Ex ib d IIC T4 Gb;
-North America: Class I Division 1, Groups A, B, C and D
Safety standards:
-Europe: EN50014, EN50020, EN50081-2, EN50270, EN50082-2;
-North America: UL 913, CSA 22.2 No.157 (SFA3009 Triple Plus+)
Dimensions: 118 x 200 x 73 mm / 4.65 x 7.8 x 2.9 inches
Weight: 880 g / 1.94 lbs
* Call to order or see accessories tab. Must specify sensors (see chart for details) and choose with / without internal pump. Charger and software sold separately.