Bilingual Technical Support (EN / ES)
Public Service, Military and First Responder Discount
30 Day Return Policy
2 Year Warranty
Free Standard Shipping (US)
The conductivity meter is a good solution for anyone who wants to check the conductivity of ultrapure water.
This conductivity meter is a compact device with an integrated temperature sensor for optimum temperature compensation.
Among other things, the conductivity meter has a very low measuring range of only 0 ... 20 μS / cm.
Furthermore, the cunductivity meter is able to accurately determine the salinity of liquids.
The conductivity meter has an automatic temperature compensation in the range of 0 ... 60 ° C.
The calibration of the conductivity meter is carried out via a three-point calibration.
For the desalting stage of water purification the conductivity meter is helpfull. Separation of salt is a necessary process and can be monitored by conductivity meter. The latter are a part of both, electrodialysis and reverse osmosis. Though, the purpose is the same, the principle of these process is different. Reverse osmosis is a successor of electrodialysis and if the latter uses electrical current, the former is based on pressure. For desalting of water also forward osmosis may be applied, which helps to separate the dissolved solutes from the pure water. Both methods are aimed at improving the pure water quality. This quality can be checked in the end by the conductivity meter.
Conductivity is a material-specific ability to conduct electrical current. The electrolytic conductivity of aqueous solutions depends on concentration of water constituents, their degree of dissociation and the valency of the cations and anions as well as the mobility of these ions, which in turn is influenced by the temperature. Our conductivity meter can accurately determine the ion content. In wastewater, the conductivity is considered as a sum parameter for the ion concentration and thus for the total salinity. With the help of our conductivity meter it is possible to make a quick and easy statement about the total content of dissolved salts in the water.
Conductivity measuring range | 0 ... 20 µS/cm 0 ... 200 µS/cm 0 ... 2000 µS/cm 0 ... 20.00 mS/cm |
Resolution | 0.01 / 0.1 / 1 |
Accuracy | ± 1 % of measuring range |
Salinity measuring range | 0.00 ... 10.00 ppt |
Resolution | 0.01 ppt |
Accuracy | ± 1 % of measuring range |
Temperature measuring range | 0 ... 60 °C / 32 ... 140 °F |
Resolution | 0.1 °C |
Accuracy | ± 1 °C |
Temperature compensation range | 0 ... 60 °C / 32 ... 140 °F |
Temperature coefficient | 2 % / °C |
Number of calibration points | 1 ... 3 |
Calibration points | 84 µS/cm 1413 µS/cm 12.88 mS/cm |
Cell constant | K=1 |
Normal media temperature | 25 °C / 77 °F |
Hold function | By pressing a button |
Automatic shutdown | 8 minutes after the last key press |
Pause | Reset to factory setting possible |
Power supply | 2 x 1.5 V AAA batteries |
Operating time | ca. 200 hours |
Dimensions | 185 x 40 mm / 7.2 x 1.5" |
Weight | ca. 100 g / 3.5 oz |