Data Logger for Temperature and Humidity PCE-AM 45

Order no.: PCE-AM 45
GTIN (EAN): 4250348723338
US$ 288.00
ex. VAT, ex. delivery costs
:
4250348723338
PCE-AM 45
Available in: 1-2 days
Your PCE Instruments Benefits
Bilingual Technical Support

Bilingual Technical Support (EN / ES)

Special Promotions

Special Promotions

Public Service, Military and First Responder Discount

Public Service, Military and First Responder Discount

30 Day Return Policy

30 Day Return Policy

2 Year Warranty

2 Year Warranty

Free Standard Shipping (US)

Free Standard Shipping (US)

Description

Data Logger for Temperature and Humidity with Beaufort scale / Wind direction display / Measuring range 0.3 ... 45.0 m/s / 0.9 ... 147 ft/s / Data memory for 960 measured values ​​/ Software for transferring the measured values ​​/ Velocity and volume flow measurement

The data logger for temperature and humidity determines the wind speed via an impeller with a diameter of 65 mm / 2.5". The anemometer can reliably determine the speed in a measuring range of 0.3 ... 45.0 m/s / 0.9 ... 147 ft/s. In addition to the speed measurement with the anemometer, a volume flow measurement can also be carried out. In addition to the normal measured value display on the anemometer, a Beaufort scale is stored. The wind strength level is displayed directly on the Beaufort scale on the anemometer.

Depending on the orientation of the impeller, the data logger for temperature and humidity can also be used to determine the wind direction. This is made possible by the anemometer's built-in gyroscope. At the same time, the current ambient temperature between 0 … 45 °C / 32 ... 113 °F is displayed on the anemometer. For optimal alignment, the telescopic arm of the anemometer can be extended up to 315 mm / 12.4".

With the integrated data memory of 960 measured values, individual measured values ​​can be saved on the data logger for temperature and humidity at the touch of a button. All measured values ​​can then be transferred to a PC via the micro USB data interface. With the software in the PCE download portal, the values ​​measured by the anemometer can be analyzed and further processed. Live measurement on the PC is also possible with the anemometer and the software.

Highlights

- Battery operation for mobile use
- Telescopic probe with a length of 270 ... 540 mm / 10.63 … 21.26“
- Impeller opening of 65 mm / 2.5"
- Velocity and volume flow measurement
- Measuring range 0.3 ... 45.0 m/s / 0.9 ... 147 ft/s
- Backlit LC display

Specification

Wind speed m/s
Measuring range 0.3 ... 45.0 m/s
Resolution 0.01 m/s
Accuracy ±3 % ±0.1 m/s of measured value
   
Wind speed ft/min
Measuring range 60 ... 8800 ft/min
Resolution 0.01, 0.1, 1 ft/min
Accuracy ±3 % ±20 ft/min of measured value
   
Wind speed knots
Measuring range 0.6 ... 88.0 knots
Resolution 0.01 knots
Accuracy ±3 % ±0.2 knots of measured value
   
Wind speed km/h
Measuring range 1.0 ... 140.0 km/h
Resolution 0.01 km/h
Accuracy ±3 % ±0.4 km/h of measured value
   
Wind speed mph
Measuring range 0.7 ... 100 mph
Resolution 0.01 mph
Accuracy ±3 % ±0.2 mph of measured value
   
Wind direction  
Measuring range 0 ... 360 °
Resolution 1 °
Accuracy - - -
   
Volume flow CMM (m³/min)
Measuring range 0 ... 999900 m³/min
Resolution 0.001 ... 100 m³/min
Adjustable area 0.001 ... 999 m²
   
CFM (FT³/min)  
Measuring range 0 ... 999900 ft³/min
Resolution 0.001 ... 100 m³/min
Adjustable area 0.001 ... 999 m³
   
Temperature measurement  °C 
Measuring range 0 ... 45 °C
Resolution 0.1 °C
Accuracy ±1.0 °C
   
°F  
Measuring range 32 ... 113 °F
Resolution 0.18 °F
Accuracy ±1.8 °F
   
Moisture measurement  
Measuring range 10 ... 90 % RH
Resolution 0.1 % RH
Accuracy ±5 % RH
   
Further specifications  
Probe length 270 ... 540 mm / 10.63 … 21.26"
Probe opening Ø65 mm / 2.5"
Interface Micro USB
Data memory 960 measured values
Power supply 4 x 1.5 V AAA batteries
Power consumption 15 ... 20 mA without background lighting
  20 ... 25 mA with background lighting
  0 ... 8 µA standby
Battery discharged display   
<4.5 V
Operating conditions 0 ... 50 °C / 32 ... 122 °F, 40 ... 80 % RH, non-condensing
Storage conditions -20 ... 60 °C / -4 ... 140 °F, < 80 % RH, non-condensing
Dimensions 70 x 194 x 35 mm / 2.7 x 7.6 x 1.3"
Weight 400 g / 14.1 oz

Delivery Scope

1 x Data Logger for Temperature and Humidity PCE-AM 45
1 x Micro USB cable
1 x Transport case
4 x 1.5 V AAA batteries
1 x Instruction manual

Downloads