Airflow Food / Hygiene Meter PCE-423N

Order no.: PCE-423N
GTIN (EAN): 4250348723253
US$ 272.00
ex. VAT, ex. delivery costs
:
4250348723253
PCE-423N
Available in: 1-2 days

Description

Airflow food / hygiene meter with data memory / Measuring range 0 ... 30 m/s (98 ft/s) /
Micro-USB interface / 3/8" tripod mount / CSV file format / Rechargeable battery /
Telescopic probe extendable up to 426 mm (16.7")


The airflow food / hygiene meter has a measuring range of up to 0 ... 30 m/s. In addition to the velocity, the hot wire anemometer can precisely measure the volume flow and temperature. The compact design of the sensors, in combination with the extendable telescopic probe, enable measurements to be taken even in places that are particularly difficult to access. This means that the hot wire anemometer can be used to measure flow in cooling fins or in supply and exhaust air ducts.

With the memory of the airflow food / hygiene meter, up to 10,000 measuring points can be recorded. The stored data can be viewed directly on the hot wire anemometer after a measurement. A transfer of the measurement data from the hot wire anemometer to a computer is made possible via the micro-USB interface. The saved data is displayed in CSV format and can therefore be analyzed and further processed as required.

The built-in 1000 mAh battery in the airflow food / hygiene meter enables mobile use. The battery is charged by the hot wire anemometer via the micro-USB interface. This means that the flow meter can be charged at any 5 V USB interface. In combination with a tripod, the hot wire anemometer can be optimally positioned. There is a 3/8" tripod holder on the rear of the hot wire anemometer.

Highlights

- Measuring range up to 30 m/s / 98 ft/s
- Rechargeable battery
- Data format in CSV
- Data memory for 10,000 measuring points
- Speed, volume flow, temperature

Specification

Speed  
Measuring range 0.00 ... 30.00 m/s
  0.0 ... 5905.5 ft/min
Resolution 0.01 m/s
  0.1 ft/min
Accuracy* ±0.10 m/s or ± 5% of full scale at 0 ... 5 m/s
  ±0.30 m/s or ±5 % of full scale at 5 ... 30 m/s
  ±19.6 ft/min or ± 5 % of full scale
  at 0 ... 984.2 ft/min
  ±59.0 ft/min or ± 5 % of full scale
  at 984.2 ... 5905.5 ft/min
*whichever is greater  
   
Volume flow  
Measuring range 0.0 ... 339120.0 m3/h
  0.0 ... 99598.0 CFM
Resolution 0.1 m3/h
  0.1 CFM
   
Temperature  
Measuring range 0 ... 50 °C
  32 ... 122 °F
Resolution 0.1 °C
  0.1 °F
Accuracy ±1 °C
  ±1.8 °F
   
Further specifications  
Telescopic probe length 210 ... 426 mm / 8.2 ... 16.7"
Telescopic probe diameter   12 mm / 0.47"
Memory 10,000 measuring points
File format CSV
Interface Micro-USB
Bracket 3/8" tripod bracket
Display 2" LCD display, 176 x 220 pixels
Measuring rate 1 Hz
Power supply (battery) internal 1000 mAh battery
Power supply (external)   5 V DC, 1 A
Operating conditions 0 ... 50 °C (32 ... 122 °F), <85 % RH, non-condensing
Storage conditions -10 ... 60 °C (14 ... 140 °F), <85 % RH, non-condensing
Dimensions
(without telescopic probe)
145 x 50 x 35 mm / 5.7 x 1.9 x 1.3"
Weight 156 g / 5.5 oz

Delivery Scope

1 x Airflow Food / Hygiene Meter PCE-423N
1 x Micro-USB cable
1 x Instruction manual