High Precision Gauss Meter PCE-MFM 2400+ICA incl. ISO Calibration Certificate

Order no.: PCE-MFM 2400+-ICA
GTIN (EAN): 4250348726308

US$ 1,227.00
ISO Calibration
ex. VAT, ex. delivery costs
:
4250348726308
PCE-MFM 2400+-ICA
Available in: 10 - 14 days
Your PCE Instruments Benefits
Bilingual Technical Support

Bilingual Technical Support (EN / ES)

Special Promotions

Special Promotions

Public Service, Military and First Responder Discount

Public Service, Military and First Responder Discount

30 Day Return Policy

30 Day Return Policy

2 Year Warranty

2 Year Warranty

Free Standard Shipping (US)

Free Standard Shipping (US)

Description

High Precision Gauss Meter PCE-MFM 2400+ICA incl. ISO Calibration Certificate
High-precision magnetic field analyzer with an accuracy of 1% / Automatic switch-off / Axial measurement / Backlight / Tesla and Gauss measurement / For static magnetic fields

Magnets find application in many processes in industry, research and quality control. Regular magnetic field measurements ensure optimal use in various areas. Continuous control of the permanent magnets prevents follow-up costs due to unplanned downtimes. The ideal auxiliary tool for checking permanent magnets is the magnetic field analyzer from PCE Instruments. The magnetic field analyzer is a compact precision instrument. It was specially developed to measure magnetism and is suitable for Tesla and Gauss measurements. The magnetic field analyzer is used wherever it goes about the field strength measurement on permanent magnets. Here, it convinces by the highest reliability and precision and at the same time, by the simplicity of the application.

Electromagnetic Field Meter / Field Analyser Application in the industry. 


Electromagnetic Field Meter / Field Analyser Application in the industry.With a measuring range of 0 to 200 mT or 200 to 2.400 mT, the magnetic field analyzer covers a wide range of measuring tasks. The magnetic field analyzer has a practical switching function and can automatically switch between the two measuring ranges. If the current value is in the range 0 to 200 mT, the magnetic field analyzer switches to the 200 mT measuring range. If the 200 mT mark is exceeded, the device automatically switches to the 2000 mT range. The display clearly informs the user about the current range.
The magnetic field analyzer allows very precise magnetic field measurements with an accuracy of 1%. Thus, with the help of the magnetic field analyzer, for example, relays and permanent magnets can be tested for the existing magnetic field. The magnetic field analyzer clearly shows the measurement results on its large display. Due to the backlight, the measured values are easy to read even in the poor lighting conditions.

The magnetic field analyzer consists of a compact display device and a sensor. The sensor uses the Hall-effect to determine the magnetic fields. The application of the magnetic field analyzer is simple and effective. Before each measurement, the sensor should be adjusted to the ambient temperature. To record the measured values, the cover must be removed and the sensor head should be placed in the middle of the magnetic field to be measured. In order to be able to read the respective maximum value correctly, the magnetic field analyzer has a hold function. At the push of a button, the magnetic field analyzer shows the measured maximum value in the negative and positive range.

Magnetometer in an application
In addition, the manufacturer has equipped the magnetic field analyzer with another practical function: if necessary, the measuring device can indicate the direction of incidence of the magnetic field lines.

In order to protect the battery of the magnetic field analyzer, the measuring instrument has an automatic switch-off. If there is no input for five minutes, the magnetic field analyzer switches off automatically and prevents the battery from being completely discharged.

Electromagnetic Field Meter / electromagnet Field analyser in an application. 


Application Areas for Magnetic Field Analyzers
The magnetic field analyzer impresses by maximum reliability, precision and user-friendliness. The magnetic field analyzer is suitable for universal magnetic measurements on industrial, mechanical and electrical materials as well as for laboratory use. Besides, the magnetic field analyzer is also used in teaching and research. The magnetic field measuring device is the ideal companion for everyone who needs to determine the properties of the permanent magnets, for example to ensure their effectiveness and to determine the magnetic field strength. The magnetic field analyzer is therefore ideal for reliable instant analyzes, it is versatile and easy to use at the same time. Due to the handy and robust design and the battery operation, the magnetic field analyzer can be used mobile. Its simple operation makes the magnetic field analyzer irreplaceable during the measurement of the field strength on permanent magnets and it is also suitable for inexperienced users. The users appreciate the reliability and accuracy of the magnetic field analyzer. The Gauss meter is used, for example, in plant engineering or mechanical engineering to check the functionality and safety of the magnetic separators or magnetic filters. This ensures that production-relevant processes can be carried out without interruptions caused by the defective separation mechanisms. Magnet manufacturers also use the magnetic field analyzer in quality control to determine the magnetic field strengths.

More info
With a measuring range of 2,400 mT, the Electromagnetic Field Meter covers a wide range of measuring tasks. The field strength meter has an accuracy of 1%. This makes the Electromagnetic Field Meter a very precise measuring device. For example, the Electromagnetic Field Meter can be used to test relays and permanent magnets for the existing magnetic field. The Electromagnetic Field Meter is therefore used in production processes or in quality control.

With the backlight on the Electromagnetic Field Meter, the measured values ​​are always easy to read even in poor lighting. Thanks to the automatic switch-off function, the Electromagnetic Field Meter automatically switches itself off after 5 minutes. This ensures that the battery of the Electromagnetic Field Meter does not discharge completely.

Highlights

- Very precise measurement technology 
- Measuring range up to 24,000 G and 2,400 mT
- Axial sensor
- For measuring static magnetic fields
- Automatic shutdown
- incl. ISO Calibration Certificate

Specification

Measuring range 0… 200 mT
  200… 2,400 mT
  0 ... 2,000 G
  2,000 ... 24,000 G
   
Accuracy ± 1% of reading
   
Resolution 0.01 mT
  0.1 g
   
Measuring direction Axial
Magnetic field Static (DC)
Unit mT, G
Power supply 1 x 9V block battery
Automatic shutdown    Automatic shutdown after 5 minutes in idle status
Modes Hold mode, measurement mode
Display Backlight digital 4-digit value display
Operating temperature         0… 50°C / 32 ... 122°F
Storage temperature-20… 50°C / -4 ... 122°F
Dimensions 185 x 97 x 40 mm / 7.28 x 3.82 x 1.57 inch
Weight310 g / < 1 lb
Sensor Hall sensor axial, cable length approx. 2 m / 6.6 ft