Our Leak Detector is a versatile instrument for the detection of halogen gases such as chlorine, fluorine, medical ethylene oxide, ethanol vapour and other refrigerants. It is used in fire extinguishing systems, air conditioning systems, cooling systems and refrigerant recovery systems to detect gases such as CFCs, HCFCs and HFCs. The leak detector offers precise measurement within the range of 0 ... 1000 ppm with a resolution of 1 ppm and a quick response time (T90) of below 30 seconds as well as a warm-up time of only 30 seconds.
The Leak Detector has an ergonomic housing and a flexible, 265 mm long universal probe that can be adapted for measurements in different environments. It utilises a semiconductor sensor for real-time measurement of gas concentration. The temperature and battery level are also shown on the colour display. The alarm settings include audible signals, colour changes of the display and vibration alarms, which are differentiated according to the gas concentration: a slow tone with intermittent vibration at values between the lower and upper limit value and a fast continuous alarm at values above the upper limit value.
Our Leak Detector offers automatic power off after 15, 30 or 60 minutes, depending on the setting, and an operating time of up to 6 hours. The Leak Detector is characterised by its compact construction, non-slip design and simple operation, making it ideal for use in various industrial and commercial applications.
Gas | |
Measurement range up to | 0 ... 1000 ppm |
Resolution | 1 ppm |
Accuracy | ±5 % FS |
Temperature | |
Measurement range up to | -10 ... +50 °C |
Resolution | 0,1 °C |
Accuracy | ±1 °C |
Temperature | |
Measurement range up to | 14 ... 122 °F |
Resolution | 0,1 °F |
Accuracy | ±2 °F |
General technical data | |
Display type | LC colour display |
Display size | 2 Inch |
Response time | 30 s |
Warm-up time | 30 s |
Operating time | 6 h |
Automatic power-off from...to | 15 ... 60 min. |
Automatic power-off can be deactivated | Yes |
Tripod thread | 1/4 inch |
Refrigerant | R12, R502, R500, R22, R32, R402A, R402B, R409A, R410A, R134a, R404A, R407C, R507, R11, R13, R113, R114, R503, R170, R600a, R1270, R123, R124, R1416, R142b, R403A, R125, R417A, R23, R1343 |
Sensor length | 265 mm |
Alarm | Acoustic, Vibration, optical |
Alarm modes | Upper alarm limit adjustable: 110 ... 990 ppm Lower alarm limit adjustable: 100 ... 890 ppm |
Menu language | English, English (GB) |
Protection class (device) | IP40 |
Weight | 177 g |
Operating conditions | -10 ... 50 °C , 10 ... 99 % RH |
Storage conditions | -10 ... 50 °C , 10 ... 99 % RH |
(Rechargeable) battery | 4 x 1,5 V AAA battery , Alkali-manganese |
Capacity | 1200 mAh |
Dimensions ( L x W x H ) | 173 x 64 x 30 mm |