The PAT tester is designed for insulation measurements with a test voltage of up to 15 kV. The measuring range from 0 ... 30 TΩ and other measuring functions make the tester versatile. With 4 quick selection buttons for common test voltages and the option of setting the voltage in 500 V steps. Pre-configured diagnostic tests, including (PI), dielectric absorption ratio (DAR) and a memory function for 200 measurements. These can be transferred to the software via the interface, which also enables the insulation measuring device to be operated. The PAT tester can also be used to measure AC and DC voltages up to 600 V. The PAT tester is supplied in a robust case that offers IP66 protection even when the lid is closed.
In the course of its normal service life, electrical insulation is exposed to various stresses that lead to its deterioration. This is caused by thermal, mechanical and chemical influences as well as moisture. Although the insulation is designed to withstand these stresses over many years, abnormal stresses can intensify the natural ageing process and drastically shorten the service life. It is therefore advisable to regularly check whether an accelerated ageing process is taking place and, if necessary, to determine whether the effects are reversible.
Direct voltage DC | |
Measuring range | 30 V ... 600 V |
Resolution | 1 V |
Accuracy | ±(2.0% v.Mw. +3 digits) |
AC voltage AC | |
Measuring range | 30 V ... 600 V |
Resolution | 1 V |
Accuracy | ±(2.0% v.Mw. +3 digits) |
Insulation resistance | |
Measuring range | 0 GΩ ... 1 GΩ |
Resolution | 0.001 GΩ |
Accuracy | ±(5% v.Mw.+5 digits) |
Insulation resistance | |
Measuring range | 1 GΩ ... 10 GΩ |
Resolution | 0.01 GΩ |
Accuracy | ±(5% v.Mw.+5 digits) |
Insulation resistance | |
Measuring range | 10 GΩ ... 100 GΩ |
Resolution | 0.1 GΩ |
Accuracy | ±(5% v.Mw.+5 digits) |
Insulation resistance | |
Measuring range | 100 GΩ ... 1 TΩ |
Resolution | 1 GΩ |
Accuracy | ±(5% v.Mw.+5 digits) |
Insulation resistance | |
Measuring range | 1 TΩ ... 10 TΩ |
Resolution | 10 GΩ |
Accuracy | ±20% |
Insulation resistance | |
Measuring range | 10 TΩ ... 30 TΩ |
Resolution | 100 GΩ |
Accuracy | ±20% |
General technical data | |
Measurement functions | HOLD, PI, DAR |
Display type | LCD |
Memory medium | Internal memory |
Memory capacity | 200 measurements |
Interface | RS232 |
Automatic switch-off | 5 min |
Automatic switch-off can be deactivated | no |
Test voltage | 500 V ... 15 kV |
Safety standard | CAT IV 600 V |
Menu language | English |
Protection class (device) | IP66 |
Protection class (additional information) | Only with closed lid |
Power supply | 100 ... 240 V | 50/60 Hz |
Plug type | Euro plug device |
Weight | 6362 g |
Dimensions (L x W x H) | 325 x 430 x 132 mm |
Operating conditions | 0 ... 40 °C , 0 ... 80 % r.H |
Storage conditions | 0 ... 40 °C , 0 ... 80 % r.H |
Capacity | 5200 mAh |