Pyrometer PCE-675 incl. Type K

Order no.: PCE-675
GTIN (EAN): 4250348720108
US$ 119.00
ex. VAT, ex. delivery costs
:
4250348720108
PCE-675
Available in: 1-2 working days
Handheld
13:1
-50 ... 550 °C / -58 ... 1022 °C
No
No

Description

Pyrometer PCE-675
 Easy-to-use infrared thermometer with red laser pointer / Measuring input for K-type / Surface temperatures / Air temperature / Humidity / Dew point temperature

The pyrometer has a 13:1 spot-to-spot ratio and can accurately measure surface temperatures and ambient humidity over a very long distance. The pyrometer brings advantages, such as a simple operation and a red sighting laser. These features allow the near perfect alignment of the pyrometer for accurate measurements. 

The pyrometer is universally applicable. The integrated flashlight allows the measuring point to be illuminated in the dark. The individual settings of the pyrometer allow a wide range of temperatures and humidity to be measured. The pyrometer does not have a fixed emission value, but has a setting span of 0.1 to 1.0, thus covering more than 90% of all temperature measurement tasks.

Highlights

- Low measurement sequence
- Emissivity adjustable between 0.1 and 1.0
- Automatic shutdown
- Switchable laser sighting aid
- Measured value display selectable between °C and °F
- Different exhibition settings
- Battery operation
- Compact and robust design

Specification

Measuring function Infrared
Measuring range -50 ... 550 °C
Resolution ≤ 1000 °C/°F: 0.1 °C/°F
  > 1000 °C/°F: 1 °C/°F
Accuracy -50 … 0 ºC: ± 3 ºC
  > 0º C: ± 1.5 % or ± 2.0
  the larger value counts
   
Measuring function Type K
Measuring range -50 … 850 ºC
Resolution ≤ 1000 °C/°F: 0.1 °C/°F
  > 1000 °C/°F: 1 °C/°F
Accuracy ± 1.5 % or ± 1.5 °C
  the larger value counts
   
Measuring function Air temperature
Measuring range -20 … 60 ºC
Resolution 0.1 °C
Accuracy 0 … 40 ºC: ± 1.0 ºC
  Other: ± 2 °C
   
Measuring function Humidity
Measuring range 0 … 100 % r.H.
Resolution 1 %
Accuracy 35 … 75 % r.H.:
  ± 3.0 % r.H.
  Other: ± 5 % r.H.
   
Measuring function Dew point
Measuring range -20 … 60 ºC
Resolution 0.1 °C
Accuracy 25 ºC, 40 … 80 % r.H.: ± 1.5 ºC
   
  Wet bulb temp.
Measuring range -20 … 60ºC
Resolution 0.1 °C
Accuracy 25 °C: ± 1.5 °C
   
Emissivity adjustable between 0.1 and 1.0
Optical resolution 13 : 1
Response time
≤ 500 ms
Spectral sensitivity 8 … 14 um
Laser ≤ 1 mW, 630 … 670 nm, class 2 laser
Automatic shutdown after one minute
Operating conditions 0 … 50 ºC / ≤ 95% r.H.
Storage conditions -20 … 70 ºC / ≤ 80 % r.H.
Power supply 9 V battery
Weight  ca. 130 g

Delivery Scope

1 x Pyrometer PCE-675
1 x Thermocouple Type-K
1 x 9 V block battery
1 x Carrying bag
1 x User manual