The SPL meter PCE-318 detects the volume from a sound level of 26 dB (A). The meter is ideal for measuring very low noises, for example, noises from computer fans. The class II noise meter with jumbo display (and at a very good price / performance ratio) is ideal for measurements of sound and noise in different environments, at work, condition monitoring, etc.
Also known as the phonometer, this device is designed to IEC 651 Type II and has a very high accuracy of ± 1.5 dB. Another advantage of this meter is the analogue output. This allows the connection of an external data logger / recorder for long-term recording.
Technical specifications | |
Measurement range | 26 ... 130 dB |
Level range selection | 6 level ranges: 26 ... 80 dB, 30 ... 90 dB, 40 ... 100 dB, 50 ... 110 dB, 60 ... 120 dB, 70 ... 130 dB |
Resolution | 0.1 dB |
Accuracy | ±1.5 dB (ref. 94 dB at 1 kHz) |
Frequency range | 31.5 Hz ... 8 kHz |
Time weighting | Fast and Slow |
Frequency weighting | A and C |
Memory | Up to 99 readings, available on the display |
Output | Analog, AC / DC |
Operating conditions | -10 ... +50 °C / +14 ... +122 °F, less than 90% RH |
Storage conditions | -10 ... +60 °C / +14 ... +140 °F, less than 75% RH |
Power | 1 x 9 V battery (PP3) |
Weight | Approx. 260 g / 0.57 lb |
Dimensions | Approx. 264 x 68 x 27 mm / 10.39 x 2.68 x 1.06" |
Standards | IEC 651 Type 2 Class 2 |
See user manual for complete technical specifications. |