Description
The torque meter can be equipped with an OC or an electrically isolated output. This means that with the MIN/OK/MAX force limits set in advance, the contacts can be switched. The circuit can be set as a pulse or continuous signal. A switching input is also installed, e.g. it can trigger storage of the data. (IN -/+)
Open collector output (OC)
where the emitter is grounded - GND.
I max=25mA / U nom=24V (PIN 2/3/4/5)
Input voltage range IN(+) / IN(-): U in=12-18V / I in max=50mA (PIN 1/6)