Current Clamp PCE-830-2-ICA incl. ISO Calibration Certificate

Order no.: PCE-830-2-ICA
GTIN (EAN):
£ 2,830.00
£ 3,396.00
ISO Calibration
price ex. (VAT / delivery)
PCE-830-2-ICA
Delivery time: 10 - 14 days
Handheld

Description

Current Clamp with 3 phases, measures power and analyses
harmonics with memory, interface and software

 

The Current Clamp is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase Current Clamp also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values. The backlit LCD, with high resolution, can show up to 35 parameters simultaneously. It can have up to 3 clips attached at the same time. In data logger mode, it can save up to 17,470 readings (3 phases / 4 conductors), in a simpler set up (1 phase / 2 conductores) it can save up to 52,400 readings, split into 85 groups. All this makes the Current Clamp the ideal instrument for taking measurements over long durations. Measurement values obtained can be sent to a computer and be processed with the analysis software which comes included. The device comes with everything needed to be measuring and analysing from the moment the device arrives. Although the Current Clamp comes calibrated from the manufacturer, an optional laboratory calibration and certificate, that meets ISO standards, can be ordered seperately with the device or when a recalibration is required.  


Highlights

- Analysis of a network of 3 phases/4 conductors, 3 phases/3 conductors, 1 phase/2 conductors, 1
  phase/3 conductors
- Measures effective real value (V 123 and I 123)
- Measures active power (W, KW, MW, GW)
- Measures apparent and reactive power (KVA, KVAR)
- Power Factor (PF), phase angle (Φ)
- Measures energy and work (Wh, KWh, KVARh, PFh)
- Measures current from 0.1mA to 3000A, allowing for the reserve power of a factory to be determined
- Large LCD that shows up to 35 parameters simultaneously (3P4W [=3 phases/4 conductors])
- CT conditions (1 to 600) and PT (1 to 3000) are programmable
- Indicates current wave forms and voltage overlap.
- 512KB of memory with programmable intervals to save data every 2 to 3000 seconds, 17,470 readings
  using the system of 3 phases / 4 conductors)
- Indicates wave forms, efficiency parameters and harmonic distortion
- Backlit LCD wth dot matrix
- Average power (AD in W, KW, MW)
- Maximum power (MD in W, KW, MW) with the programmable period
- Analysis of harmonic distortion up to a curvature of 99
- Indication of up to 50º form of harmonic wave
- Indication of the wave form with maximum value (1024 readings / period)
- Analysis of absolute distortion (%THD-F)
- Diagram of graphic equilibrium with parameters of a 3 phase system
- Detects up to 28 transistors (time and cycles) with a programmable threshold (%)
- Relation of 3 phases of voltage or asymmetrical current (VUR)
- Factor of 3 phases of voltage and asymmetrical current (d0%, d2%)
- USB port (optically insulated)
- Integrated timer and calendar to record data

Specification

Technical Specifications
Measurement values Measurement ranges / resolution / accuracy
PCE-830 + PCE-6801
Watts AC (50 Hz or 60 Hz, PF 0.5 up to 1)
5.0 W to 999.9 W / 0.1 W / ±1% ±0.8 W
1.000 kW to 9.999 kW / 0.001 kW / ±1% ±8 W
10.00 kW to 99.99 kW / 0.01 kW / ±1% ±80 W
100.0 kW to 999.9 kW / 0.1 kW / ±1% ±0.8 kW
1,000 kW to 9,999 kW / 1 kW / ±1% ±8 kW
PCE-830 + PCE-6802
Watts AC (50 Hz or 60 Hz, PF 0.5 up to 1)
5.0 W to 999.9 W / 0.1 W / ±1% ±0.8 W
1.000 kW to 9.999 kW / 0.001 kW / ±1% ±8 W
10.00 kW to 99.99 kW / 0.01 kW / ±1% ±80 W
100.0 kW to 999.9 kW / 0.1 kW / ±1% ±0.8 kW
1000 kW to 9999 kW / 1 kW / ±1% ±8 kW
0.000 MW to 9.999 MW / 0.001 MW / ±1% ±80 kW
PCE-830 + PCE-3007
Watts AC (50 Hz or 60 Hz, PF 0.5 up to 1)
10.0 W to 999.9 W / 0.1 W / ±1% of measurement range
1.000 kW to 9.999 kW / 0.001 kW / ±1% of measurement range
10.00 kW to 99.99 kW / 0.01 kW / ±1% of measurement range
100.0 kW to 999.9 kW / 0.1 kW / ±1% of measurement range
1,000 kW to 9,999 kW / 1 kW / ±1% of measurement range
PCE-830 + PCE-6801
Current AC (50 Hz or 60 Hz, auto range select, TRMS)
0.04 A to 1 A / 0.001 A / ±0.5% ±0.05 A
0.4 A to 10.0 A / 0.01 A / ±0.5% ±0.05 A
4 A to 100.0 A / 0.1 A / ±1.0% ±0.5 A
PCE-830 + PCE-6802
Current AC (50 Hz or 60 Hz, auto range select, TRMS)
10.00 A / 0.01 A /
4 A to 100.0 A / 0.01 A / ±0.5% ±0.5 A
40 A to 1000.0 A / 0.1 A / ±0.5% ±5 A
PCE-830 + PCE-3007
Current AC (50 Hz or 60 Hz, auto range select, TRMS)
0 to 300 A / 0.1 A / ±1.0% of measurement range
300.0 A to 999.9 A / 0.1 A / ±1.0% of measurement range
1,000 A to 3,000 A / 1 A / ±1.0% of measurement range
Voltage AC (50 Hz or 60 Hz, TRMS) 20.0 V ... 500.0 V / 0.1 V / ±0.5 % ±5 digits
(grounded)
20.0 V ... 600.0 V / 0.1 V / ±0.5 % ±5 digits
(phase to phase)
Harmonic distortionof AC voltage 1º to 20º / 0.1% / ±1.0%
21º to 49º / 0.1% / 4% of reading ±2.0%
50º to 99º / 0.1% / 6% of reading ±2.0%
PCE-830 + PCE-6801
Harmonics of AC current in %
1º to 20º / 0.1% / ±0.2% of reading ±1.0%
11º to 20º / 0.1% / ±2% of reading ±1.0%
21º to 50º (A)/ 0.1% / ±5% of reading ±1.0%
21º to 50º (mA)/ 0.1% / ±10% of reading ±1.0%
51º to 99º / 0.1% / ±35% of reading ±1.0%
PCE-830 + PCE-6802
Harmonics of AC current in %
1º to 10º / 0.1% / ±2%
21º to 49º / 0.1% / 4% of reading ±2.0%
50º to 99º / 0.1% / 6% of reading ±2.0%
PCE-830 + PCE-3007
Harmonics
of AC current in %
1º to 10º / 0.1% / ±2%
21º to 49º / 0.1% / ±6%
50º to 99º / 0.1% / ±10%
PCE-830 + PCE-6801 / PCE-830 + PCE-6802
Power Factor (PF)
0.00 to 1.00 / 0.01 / ±0.04
PCE-830 + PCE-3007
Power Factor (PF)
0.000 to 1,000 / 0.001 / ±0.04
PCE-830 + PCE-6801 / PCE-830 + PCE-6802
Phase angle (Phi)
-180° to 180° / 0.1° / ±1°
PCE-830 + PCE-3007
Phase angle (Phi)
0° to 180° / 0.1° / ±2°
PCE-830 + PCE-6801
Total harmonic distortion
0.0 to 20.0% / 0.1% / ±1%
20.0% to 100% / 0.1% / ±3% of reading ±5%
100% to 999.9% / 0.1% / ±10% of reading ±10%
PCE-830 + PCE-6802
Total harmonic distortion
0.0 to 20.0% / 0.1% / ±2%
20.0% to 100% / 0.1% / ±6% of reading ±1%
100% to 999.9% / 0.1% / ±10% of reading ±1%
PCE-830 + PCE-3007
Total harmonic distortion
0.0 to 20.0% / 0.1% / ±2%
20.0% to 100% / 0.1% / ±6% of reading ±1%
100% to 999.9% / 0.1% / ±10% of reading ±1%
Maximum measurement of AC voltage and current 50 Hz / 19 µS / ±5% ±30 digits
60 Hz / 16 µS / ±5% ±30 digits
Peak value measurement of AC voltage and current 1.00 to 99.99 / 0.01 / ±5% ±30 digits
Frequency range in automatic mode 45 Hz to 65 Hz / 0.1 H z / 0.1 Hz
Memory 512 kB for a maximum 52,420 readings taken by 1 phase / 2 conductors
Port USB
Software and cable included, for Windows 2000, XP, ME
Display backlit LCD with dot matrix
Power 8 AA batteries (Mignon)
Dimensions 257 mm x 155 mm x 57 mm
10.1 in x 6.10 in x 2.24 in
Weight 1.16 kg / 2.56 lbs
Operating conditions max. 85% relative humidity
-10º C to 50º C / 14º F to 122º F
Type of protection / standards IEC 61010, 600 V/CAT III
Set 1:
PCE-830 + PCE-6801 amp clamp (100 A)

- Electrical conductor pick-up: 30 mm / 1.2 in diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Dimensions: 210 mm x 62 mm x 36 mm / 8.2 in x 2.4 in x 1.4 in
- Weight: 200 g / 7 oz
Set 2:
PCE-830 + PCE-6802 amp clamp (1000 A)

- Electrical conductor pick-up: 55 mm / 2.2 in diameter
- Range selection: manual (10 A, 100 A, 1,000 A)
- Dimensions: 244 mm x 97 mm x 46 mm / 8.6 in x 97 in x 46 in
- Weight: 600 g / 1.3 lbs
Set 3:
PCE-830 + PCE-3007 flexible amp clamp (3000 A)
- Electrical conductor pick-up: 170 mm / 6.69 in diameter
- Minimum radial curve : 35 mm / 1.4 in
- Length of electrical conductor: 610 mm / 24.0 in
- Diameter of electrical conductor: 14 mm / 0.55 in
- Dimensions (Box): 130 mm x 80 mm x 43 mm / 5.1 in x 3.1 in x 1.6 in
- Weight: 410 g / 14.4 oz
Outline of the PCE-830
Connecting the amp clamps to the PCE-830:
1. Turn on the device.
2. Push the "1f3f" key until "3P3W" appears on the display for 3 phases / 3 conductors.
3. Connect the 3 test cables from the voltage with L1, L2, L3 and the analyser. The amp clamps are connected, as seen in the image to the right, between the device and the circuit.
4. The results can then be seen on the display.

Delivery Scope

1 x PCE-830-2 Current Clamp
3 x Amp clamps - Depending on the set ordered (PCE-6801, PCE-6802 or PCE-3007)
4 x Alligator clips
4 x Safety test lines (3m long)
8 x Batteries
1 x Mains adaptor
1 x Carrying case
1 x USB cablem software
1 x User's manual
1 x ISO Calibration Certificate

Calibration certificates are issued specifically for the customer and are excluded from the right of return.