Using the pool pH meter makes determining the pH value particularly easy. In order to carry out a measurement with the pool pH meter, the protective cap of the electrode must first be removed.Pool pH meter in use.The electrode can be cleaned quickly and thoroughly. After cleaning the electrode with a pH-neutral liquid, the pool pH meter is immediately ready for use. The pool pH meter can be activated quickly and easily at the push of a button. Now the electrode can be immersed in the pool water. Within a few seconds, the display of the pool pH meter shows the measurement results clearly legible. The practical data hold function of the pool pH meter enables the measured values to be saved. To freeze the measured value, a single push of the “Hold” button is sufficient. The manufacturer recommends cleaning the electrode of the pool pH meter with a pH-neutral liquid after each measurement. Alternative electrodes can also be connected to the pool pH meter using the BNC connector. Thanks to the ease of use, the pH meter can be easily adjusted to another electrode.
The pool pH meter is the ideal measuring instrument for every swimming pool owner who values optimal water quality. The pool pH meter for monitoring swimming pool water.Unstable pH levels can unbalance pool water, cause skin and eye irritation, damage fittings and affect the way pool chemicals work. The pool pH meter from PCE Instruments combines ease of use and reliability with a compact design. The battery-operated pool pH meter is small, handy and robust and therefore ideally suited for mobile use. Thanks to its properties and easy handling, the pool pH meter is also suitable for inexperienced users. The pool pH meter guarantees maximum reliability and precise measurement results.
PCE-PH 16 | |
Measuring range | 0.00 ... 14.00 pH |
Measurement accuracy | ± 0.1 pH (at 20°C / 68°F), ± 0.2 pH |
Resolution | 0.01 pH |
Adjustment | Manual one-point adjustment |
Power supply | 3 x 1.5V (LR44 AG-13 battery) |
Working environment | 0 ... 50°C / 32 ... 122°F |
Dimensions | 175 x 51 x 25 mm / 6.9 x 2 x 1 in |
Weight | Approx. 57 g / < 1 lb |
PCE-TUM 20 | |
Measuring range | 0.00 to 50.0 NTU and 50 to 1000 NTU |
Resolution | 0.01 and 1 NTU |
Accuracy | ± 5% of meas. Measuring range or ± 0.5 NTU |
Light source | LED, infrared at 850 nm |
Lifespan | Almost unlimited |
Light detector | Photodiode |
Measurement time | < 10 sec. |
Battery | 6 x 1.5V AAA batteries |
Environmental conditions | Max. 50°C / 122°F, max. 85% RH |
Dimensions (HxWxD) | 155 x 76 x 62 mm / 6.1 x 2.8 x 2.4 in |
Weight | 320 g / < 1 lb |
PCE-CM 41 | |
Conductivity measuring range EC | 0 ... 2000 µS / cm, 0 ... 20 mS / cm |
Resolution conductivity EC | 1 µS / cm, 0.01 mS / cm |
Accuracy conductivity EC | ± 1% of the measuring range |
Measuring range for salinity TDS | 0 ... 2000 mg / l (ppm), 20000 mg / l (ppm) |
Resolution salinity TDS | 1 ppm (< 1320 ppm), 10 ppm (> 1320 ppm) |
Accuracy salinity TDS | ± 3% of the measuring range |
Measuring range temperature | 0 ... 60°C / 32 ... 140°F |
Resolution temperature | 0.1°C / 0.18°F |
Accuracy temperature | ± 0.8°C / 1.5°F |
TDS | 1 ppm (< 1320 ppm) 10 ppm (> 1320 ppm) |
Calibration | 1413 µS / cm |
Surroundings | 0 ... 60°C / 32 ... 140°F, < 80% rh |
Power supply | 4 x 1.5V batteries type AAA (incl.) |
Dimension | 186 x 40 mm / 7.3 x 1.6 in (HxW) |
Weight | 130 g / < 1 lb |