Gauss meter for AC and DC magnetic fields /
Precision and standard sensor / LCD display / SD data logger / Serial interface / Tabletop device
The radiation detector is used in the laboratory and quality assurance to measure the strength of magnetic fields. The radiation detector is delivered with two different sensors. There is a magnetic field sensor for general measurements in the Gauss and milli-Tesla range, as well as a precision sensor for measurements in the milli Gauss and micro-Tesla range. The radiation detector sensors have automatic temperature compensation. The radiation detector can be used for measurements of DC and AC magnetic fields. The radiation detector shows the polarity of the DC magnetic field on the display next to the measured value. This precise radiation detector can be connected to a PC via serial interface for measurement value analysis.
The radiation detector also has a data logging function. The radiation detector is able to save the measured values on an SD memory card at a preset interval during the measurement. In addition to interval storage, up to 99 individual measured values can be stored in the memory at the push of a button. The measurement data are stored by the radiation detector on the SD card in Excel format. This has the advantage that no additional software has to be used for the radiation detector.
- Tabletop device with 2 sensors
General Probe Range: 0-3000 milli-Tesla (0-30,000 Gauss)
Precision Probe Range: 0-300 micro-Tesla (0-3000 milli-Gauss)
- For static and changing magnetic fields
- Highly accurate Transverse Hall sensor
- Different units selectable (mG / µT)
- Data storage on SD memory card
- Automatic shutdown
- Serial interface
- Max.- min.- hold function
Measuring function DC magnetic field precision sensor | |
Measuring range | ± 30µT |
± 300 µT | |
± 300 mG | |
± 3000 mG | |
Resolution | 0.01 µT |
0,1μT | |
0.1 mG | |
1 mG | |
Accuracy | ± (2% of MB + 2 mG) |
@ ± 100µT / 1000 G | |
Measuring function DC magnetic field standard sensor | |
measuring range | ± 300 mT |
± 3000 mT | |
± 3000 G. | |
± 30000 G. | |
Resolution | 0.01 mT |
0.1 mT | |
0.1 g | |
1 G | |
Accuracy | ± (5% of VAT + 10 Dgt) |
Measuring function AC magnetic field standard sensor 50/60 Hz | |
Measuring range | 30μT |
300 µT | |
300 mG | |
3000 mG | |
Resolution | 0.01 µT |
0,1μT | |
0.1 mG | |
1 mG | |
Accuracy | ± (2% of MB + 2 mG) |
@ 0 ... 100µT / 1000 G | |
Measuring function AC magnetic field precision sensor 50/60 Hz | |
Measuring range | 30μT |
300 µT | |
300 mG | |
3000 mG | |
Resolution | 0.01 µT |
0,1μT | |
0.1 mG | |
1 mG | |
Accuracy | ± (2% of MB + 2 mG) |
@ 0 ... 100µT / 1000 G | |
Measuring function AC magnetic field standard sensor 50/60 Hz | |
Measuring range | 150 mT |
1500 mT | |
1500 g | |
15000 G. | |
Resolution | 0.01 mT |
0.1 mT | |
0.1 g | |
1 G | |
Accuracy | ± (5% of VAT + 10 Dgt) |
General technical data | |
Measuring rate | 1 second |
Measuring direction | Uniaxially |
Display | LCD display |
Features | Data hold / max. Min. Memory |
Storage | Data logger single value memory |
Data logger storage rate | 1, 2, 5, 10, 30, 60, 120, 300, 600, 1800, 3600 s |
Interface | Serial |
Environmental conditions | 0 ... 50°C / 32 ... 122°F, max. 85% RH |
Power supply | 6 x 1.5V AA batteries |
Optional 9V power supply | |
Current consumption | Approx. 138-mA |
Dimension | |
Device | 292 x 236 x 98 mm / 11.5 x 9.3 x 3.9 in |
Precision sensor | 195 x 25 x 19 mm / 7.7 x 1 x 0.7 in |
Standard sensor | 177 x 29 x 17 mm / 7 x 1.1 x 0.7 in |
Weight | 275 g / < 1 lb |
1 x Radiation Detector PCE-MFM 4000
1 x Standard Sensor Range: 0-3000 milli-Tesla (0-30,000 Gauss)
1 x Precision Sensor Range: 0-300 micro-Tesla (0-3000 milli-Gauss)
1 x SD memory card
6 x 1.5V AA batteries
1 x Instruction manual