Anemometer with a volumetric flow hood PCE-VA 20-SET
Measurement of wind speed, volumetric flow rate, temperature, humidity, dew point and wet bulb temperature / Backlight / 10 cm impeller diameter
Extreme value measurement / HOLD function / automatic switch-off
The PCE-VA 20 anemometer in a set with a volumetric flow hood is used to measure the flow velocity and volumetric flow rate in the area of ventilation and air-conditioning systems maintenance. In addition, the anemometer with the volumetric flow hood can measure climate parameters, such as temperature and humidity. From this, the meter calculates the dew point (DP) and the wet bulb temperature (WBT). All the measured and calculated parameters are displayed in the anemometer with the volumetric flow hood on the two-line LC-display. In the upper part, the flow velocity, humidity and the average value, in the mean value mode, are displayed. Depending on the measuring mode, the lower part of the display shows the temperature, volumetric flow, wet bulb temperature and the dew point. For a better and faster evaluation of the measured values, maximum, minimum and average measurements are also available for the user of the anemometer with the volumetric flow hood.
The anemometer is powered by four 1.5V AAA batteries. So, the anemometer with volume flow hood can be used as a mobile device. Besides anemometer, this measuring set is delivered also with 2 volumetric flow hoods, which can be put on the display unit directly. The volumetric flow hoods are suitable for measurements of the air mass at the round and square duct exits or inlets.
- Measures air flow velocity, volume flow, relative humidity, air temperature, dew point temperature and wet-bulb temperature
- Air flow velocity range: 0.2 ... 30 m/s (39.4 ... 5905.5 fpm)
- Accuracy: ±(1.5% of measured value + 0.3 m/s) when less than 20 m/s, ±(3% of measured value + 0.3 m/s) when more than 20 m/s
- Resolution: 0.1
- Includes 2 x capture hoods (1 x round 210 mm / 8.3 in Ø, 1 x square 346 x 346 mm / 13.6 x 13.6 in)
- 10 cm / 3.9 in Ø fan impeller
- Easy-to-read backlit LCD
- Display hold, average value, maximum value, minimum value, battery-saving automatic power off, low-battery indicator, and metric or imperial unit selection functions
Technical Specification | ||
Air flow velocity measuring range |
|
|
Air flow velocity accuracy | <20 m/s: ±(1.5% of rdg. + 0.3 m/s) >20 m/s: ±(3% of rdg. + 0.3 m/s) |
|
Air temperature measuring range | -20 ... 60 °C / -4 ... 140 °F | |
Air temperature accuracy | ±0.6 °C | |
Air temperature resolution | 0.1 °C / °F | |
Humidity measuring range | 0.1 ... 99.9 % r.H. | |
Humidity accuracy | ±3 % r.H. (at 25 °C / 77 °F and 10...90 % r.H.) else: ±5 % r.H. |
|
Humidity resolution | 0.1 % r.H. | |
Temperature response time | 60 seconds | |
Humidity response time | 60 seconds | |
LCD update | 1 x per second | |
Wet bulb temperature display | -20 ... +59.9 °C / -4 ... 139.8°F | |
Dew point temperature display | -5 ... +59.9 °C / 23 ... 139.8°F | |
Volume flow display | 0 ... 99999 m³/min | |
Volume flow resolution | 0.1 m³/min (0...9999,9 m³/min) 1 m³/min (10000...99999 m³/min) |
|
Automatic shutdown | after 20 minutes of inactivity | |
LCD size | 32.5 x 54 mm / 1.28 x 2.13" (H x W) | |
Power supply | 4 x 1.5 V AAA batteries | |
Operating conditions | 0 ... +50 °C / 32 ... 89.6°F, <80 % r.H. | |
Storage conditions | -10 ... +50 °C / 14 ... 89.6°F, <90 % r.H. | |
Dimensions | 269 x 106 x 51 mm / 10.6 x 4.1 x 2.0" | |
Weight | ca. 200 g / 7 oz |
1 x Anemometer with a volumetric flow hood PCE-VA 20
1 x Square flow hood
1 x Round flow hood
4 x AAA batteries
1 x User manual
1 x Carrying case