The Clamp on Tester PCE-DC 2 has been designed to detect, indirectly, AC/DC current and ohms. The Clamp on Tester has white LEDs integrated to allow for the point of measurement to be illuminated, and a function to test the voltage without contact. The reduced dimensions of this Clamp on Tester allow for measurements to be taken in places with limited access. The backlight display ensures that it is easy to read, even in places with limited light available, such as electrical cabinets or in cabling ducts. Testing voltage without contact helps when detecting dangerous power lines, and it allows makes it easier to detect the location of cuts in power lines.
Alternating current (50/60 Hz, TRMS) | |
Measuring range | 0 ... 200.0 A |
Resolution | 0.1 A |
Accuracy | ±(2.5 % + 8 digits) |
Direct current | |
Measuring range | 0 ... 200.0 A |
Resolution | 0.1 A |
Accuracy | ±(2.0 % + 5 digits) |
DC voltage | |
Measuring range | 0 ... 600.0 V |
Resolution | 0.1 V |
Accuracy | ±(1.0 % + 2 digits) |
AC voltage (50/60 Hz, TRMS) | |
Measuring range | 0 ... 600.0 V |
Resolution | 0.1 V |
Accuracy | ±(1.5 % + 8 digits) |
Resistance | |
Measuring range | 0 ... 999.9 Ω |
Resolution | 0.1 Ω |
Accuracy | ±(1.5 % + 8 digits) |
Further specifications | |
Current clamp opening |
18 mm / 0.7" |
Continuity test | <30Ω, test current <0.5 mA |
Battery indicator | "BAT" low battery indicator |
Measuring range exceeded | "OL" display when measuring range is exceeded |
Measurement rate | 10 Hz for the reading |
40 Hz for the bar graph at DC, | |
DC voltage and resistance measurement | |
Input impedance | 1.0 MΩ when measuring the voltage |
Display | LC display with backlight |
Peak measurement response time | <10 ms |
(PEAK Hold) | |
Response time of the largest and | <50 ms |
smallest measured value (MAX / MIN hold) | |
Operating conditions | -10 ... 50 °C / 14 ... 122 °F, max. 3000 m / 9842 ft above sea level |
Storage conditions | -30 ... 60 °C / -14 ... 140 °F, max. 10,000 m / 32,808 ft above sea level |
Ambient humidity | max. 90 % (0 ... 30 °C / 32 ... 86 °F) |
(RH, non-condensing) | max. 75 % (30 ... 40 °C / 86 ... 104 °F) |
max. 45 % (40 ... 50 °C / 104 ... 122 °F) | |
Power supply | 2 x 1.5 V AAA batteries |
Automatic shutdown | after 10 minutes without operation |
Degree of pollution | 2 |
Standards | CAT III 600 V, CAT IV 300 V |
Dimensions | 164 x 65 x 32 mm / 6.45 x 2.56 x 1.26" |
Weight | 175 g / 6.17 oz |