Clamp-on Tester PCE-PCM 3

Order no.: PCE-PCM 3
GTIN (EAN): 4250348719089
£ 210.00
£ 252.00
Wireless
price ex. (VAT / delivery)
:
4250348719089
PCE-PCM 3
Delivery time: 1-2 working days

Description

Clamp-on tester PCE-PCM 3
Digital multimeter for single-phase measurement / NCV measurement / W / VA / Var / Inrush Current / 1000 A AC Current Measurement / Bluetooth Interface / Frequency Measurement / Backlight / Voltage measurement / 750 kW power 

With the clamp-on tester AC currents of up to 1000 A AC can be measured easily. At the same time, voltages of up to 1000V AC / DC can be measured with the clamp-on tester. Thus, with the power current clamp, apparent power, reactive power and active power measurements up to 750 KW are possible. Another function of the clamp-on tester is the measurement of the inrush current. Many consumers have a tremendously high current at the moment of switch-on. With a conventional clamp-on tester such a measurement is not possible. For the clamp-on tester this is not a problem.

With the NCV (Not Connected Voltage) function of the clamp-on tester, it can be checked whether a voltage is applied to a line without performing a contacting measurement. This makes the work much easier for the user thanks to the clamp-on tester. In addition to the measuring function, the clamp-on tester can also be connected to a terminal via the Bluetooth interface. Via this Bluetooth interface, the measured data can be transmitted directly from the clamp-on tester to the terminal, where it can be logged, analyzed and sent.

Highlights

- Apparent / active / reactive power
- Measurement up to the 20th harmonic
- "Not Connected Voltage" function
- Inrush current measurement
- Current measurement up to 1000 A AC
- Bluetooth interface

Specification

Ambient conditions 23°C / 73.4°F ± 5°C / 41°F, < 75% RH

Measuring function    
Current measurement AC    
Measuring range Resolution Accuracy
60 A 0.01 A
± 2% + 8 Dgt
600 A 0.1 A ± 2% + 8 Dgt
1000 A 1 A ± 2% + 8 Dgt
     
Maximum input current: 1000 A AC
Frequency range: 40 .... 400 Hz
     
Measuring function    
Inrush current AC    
Measuring range Resolution Accuracy
60 A 0.01 A For reference only
600 A 0.1 A ± 5% + 60 Dgt
1000 A 1 A ± 5% + 60 Dgt
     
Integral time: 100 ms  
Measuring range: 20 ... 1000 A  
Frequency range: 40 .... 400 Hz
     
Measuring function    
Voltage measurement DC    
Measuring range Resolution Accuracy
6V 0.001V ± 0.5% + 5 Dgt
60V 0.01V ± 0.5% + 5 Dgt
600V 0.1V ± 0.5% + 5 Dgt
1000V 1V ± 0.8% + 4 Dgt
     
Input impedance: 10 MΩ
Maximum input voltage: 750V AC (rms value) or 1000V DC
     
Measuring function    
Voltage measurement AC    
Measuring range Resolution Accuracy
6V 0.001V ± 0.6% + 4 Dgt
60V 0.01V ± 0.6% + 4 Dgt
600V 0.1V ± 0.6% + 4 Dgt
1000V 1V ± 0.8% + 4 Dgt
     
Input impedance: 10 MΩ
Maximum input voltage: 750V AC (rms value) or 1000V DC
Frequency range: 40 ... 400 Hz
     
Measuring function    
Frequency measurement with    
The current measuring function    
Measuring range Resolution Accuracy
99.99 Hz 0.01 Hz
± 1.5% + 5 Dgt
999.9 Hz 0.1 Hz ± 1.5% + 5 Dgt
     
Measuring range: 10 ... 1 kHz
Measuring range of the input signal: > 20 AAC (rms value)
The input current increases with the measuring frequency.
Maximum input current: 1000 AAC (rms value)
     
Measuring function    
Frequency measurement with the    
Voltage measurement function    
Measuring range Resolution Accuracy
99.99 Hz 0.01 Hz ± 1.5% + 5 Dgt
999.9 Hz 0.1 Hz ± 1.5% + 5 Dgt
9,999 kHz 0.001 kHz ± 1.5% + 5 Dgt
     
Measuring range: 10 ... 10 kHz
Measuring range of the input signal: > 1V AC (rms value)
The input current increases with the measuring frequency.
Maximum input voltage: 1000V AC (rms value)
     
Measuring function    
Frequency measurement     
Measuring range Resolution Accuracy
9,999 Hz 0.001 Hz ± 0.3% + 5 Dgt
99.99 Hz 0.01 Hz ± 0.3% + 5 Dgt
9,999 kHz 0.1 Hz ± 0.3% + 5 Dgt
999.9 Hz 0.001 kHz
± 0.3% + 5 Dgt
99.99 kHz 0.01 kHz ± 0.3% + 5 Dgt
999.9 kHz 0.1 kHz ± 0.3% + 5 Dgt
9,999 MHz 0.001 MHz ± 0.3% + 5 Dgt
     
Overvoltage protection: 1000V DC or 750V AC (rms value)
Range of voltage input> 2V
(as the input voltage increases, so does the frequency)
     
Measuring function    
Duty cycle    
Measuring range Resolution Accuracy
0.1 ... 99.9% 0.1% ± 0.3% + 5 Dgt
     
Frequency range: 10 ... 10 kHz
Voltage range: 2 ... 250V AC (rms value)
(The voltage increases with the frequency)
 
Duty cycle with the Frequency range: 10 ... 1 kHz
Current measurement function Input current: 20 ... 1000 AAC (rms value)
 
Duty cycle with the Frequency range: 10 ... 1 kHz
Voltage measurement function Input current: 1 ... 750V AC (rms value)
  Input impedance: 1MΩ
     
Measuring function    
Resistivity
   
Measuring range Resolution Accuracy
600 Ω 0.1 Ω ± 0.8% + 3 Dgt
6 kΩ 0.001 kΩ ± 0.8% + 3 Dgt
60 kΩ 0.01 kΩ ± 0.8% + 3 Dgt
600 kΩ 0.1 kΩ ± 0.8% + 3 Dgt
6 MΩ 0.001 MΩ ± 2% + 5 Dgt
60 MΩ 0.1 MΩ ± 2% + 5 Dgt
     
Measuring voltage: approx. 0.78V
Overvoltage protection: 750V DC, 1000V AC (rms value)
     
Measuring function    
Continuity test
   
Measuring range Resolution Accuracy
600 Ω 0.1 Ω -
     
Acoustic signal at < 50 Ω
Test voltage: 1.48V
Overvoltage protection: 750V DC, 1000V AC (rms value)
     
Measuring function    
Capacitance measurement
   
Measuring range Resolution Accuracy
9.999 nF 0.001 nF ± 3% + 5 Dgt
99.99 n.f. 0.01 nF ± 3% + 5 Dgt
999.9 nF 0.1 nF ± 3% + 5 Dgt
9.999 μF 0.001 μF ± 3% + 5 Dgt
99.99 μF 0.01 μF ± 3% + 5 Dgt
999.9 μF 0.1 μF ± 3% + 5 Dgt
9,999mF 0.001 mF ± 3% + 5 Dgt
99.99 mF 0.01 mF ± 3% + 5 Dgt
     
Overvoltage protection: 750V DC, 1000V AC (rms value)
     
Measuring function    
Diode measurement
   
Measuring range Resolution Accuracy
3V 
0.001V
-
     
DC anode side: approx. 1-mA
DC cathode side: approx. 3.2V
Overvoltage protection: 750V DC, 1000V AC (rms value)
     
Measuring function    
Single phase power measurement
   
Measuring range Resolution Accuracy
3 W / VA / Var 0.01 W / VA / Var ± 3% + 5 Dgt
100 W / VA / Var 0.1 W / VA / Var ± 3% + 5 Dgt
4000 W / VA / Var 1 W / VA / Var ± 3% + 5 Dgt
10 kW / VA / var 0.01 kW / VA / Var ± 3% + 5 Dgt
100 kW / VA / var 0.1 kW / VA / Var ± 3% + 5 Dgt
750 kW / VA / var 1 kW / VA / Var ± 3% + 5 Dgt
     
Smallest measuring current: 1-mA
Smallest measuring voltage: 1V
     
Measuring function    
Power factor capacitive / inductive
   
Measuring range Resolution Accuracy
0.1 ... 1
0.001
± 5% + 5 Dgt
     
Smallest measuring current: 1-mA
Smallest measuring voltage: 1V
     
Measuring function    
Harmonics measurement
   
Measuring range Resolution Accuracy
1 - ± 3% + 10 Dgt
2 ... 6 - ± 3.5% + 10 Dgt
7 ... 8 - ± 4.5% + 10 Dgt
9 ... 10 - ± 5% + 10 Dgt
11 ... 15 - ± 7% + 10 Dgt
16 ... 20 - ± 10% + 10 Dgt
     
Smallest measuring current: 1-mA
Smallest measuring voltage: 1V
The resolution depends on the voltage measuring range
     
General specifications    
Measuring range Automatically and manually adjustable
Maximum voltage range 1000V DC or 750V AC
Maximum working height 2000 m / 6561 ft
Display LCD
Maximum display 5999 Dgt.
Overrange "OIL"
Measuring range underflow "-OL"
Measuring rate 3 Hz
Automatic shutdown After 30 minutes
Power supply 9V block battery
Battery indicator Icon if the battery voltage is too low
Temperature coefficient 0.1 x accuracy x °C / °F*
Operating conditions 0 ... 40°C, 32 ... 104°F
Storage conditions -10 ... 60°C, 14 ... 140°F
Dimensions 238 x 92 x 50 mm / 9.4 x 3.6 x 2 in  
Weight About 420 g / < 1 lb (with batteries)
   
Accuracies are given at ambient conditions of 18 ... 28°C / 65 ... 83°F.
*The temperature is the difference between the temperature of the operating conditions and the current ambient temperature.
   
Example:  
Is the current ambient temperature greater than the temperature of the operating conditions
(50°C / 122°F (current ambient temperature)) - (40°C / 104°F (operating temperature) 
= 10°C / 50°F
Is the current ambient temperature less than the temperature of the operating conditions
(0°C (operating temperature)) - (-5°C / 23°F (current ambient temperature)) 
= 5°C / 41°F
 


Delivery Scope

1 x Clamp-on tester PCE-PCM 3
1 x Transport bag
1 x Test lead set
1 x 9V block battery
1 x User manual