Price excl. VAT &. delivery
2 year Warranty
Measuring range: 0 ... 14 pH
Material: glass
Temperature range: 0 ... 60 °C / 32 ... 140 °F
Connector: BNC
Cable: 1 m / 3.2 ft
pH measurement |
|
Measurement range | 0 ... 14.0 pH |
Resolution | 0.01 pH |
Accuracy | ±0.02 pH + 2 digits |
Calibration | 3 points (pH 4, pH 7, and pH 10) |
Temperature compensation | Automatic with additional temperature sensor (0 ... 60 ºC / 32 ºF ... 140 ºF) or manual (0 ... 100 ºC / 32 ºF ... 212 ºF) |
Redox measurement (optional) | |
Measurement range | 1999 ... 0 ... 1999 mV |
Resolution | 1 mV |
Accuracy | ± 0.5 % + 2 digits |
Conductivity measurement | |
Measurement range | 0 ... 200 µS/cm, 0.2 ... 2.0 mS/cm, 2 ... 20.0 mS/cm, 20 ... 200 mS/cm |
Resolution | 0.01 µS/cm, 0.001 mS/cm, 0.01 mS/cm, 0.1 mS/cm |
Accuracy | ±2 % of the measurement range + 1 digit |
Calibration | 1413 mS/cm |
Temperature compensation | Automatic (0 ... 60 ºC / 32 ºF ... 140 ºF) |
Total dissolved solids (TDS) measurement |
|
Measurement range | 0 ... 132 ppm, 132 ... 1320 ppm, 1320 ... 13200 ppm, 13200 ... 132000 ppm |
Resolution | 0.1 ppm, 1 ppm, 10 ppm, 100 ppm |
Accuracy | ±2 % of the measurement range + 1 digit |
Temperature compensation | Automatic (0 ... 60 ºC / 32 ºF ... 140 ºF) |
Salt content measurement | |
Measurement range | 0 ... 12 % (of weight) |
Resolution | 0.1 % |
Accuracy | ±0.5 % of the measurement range |
Temperature compensation | Automatic (0 ... 60 ºC / 32 ºF ... 140 ºF) |
Oxygen measurement (optional) | |
Measurement range | 0 ... 20 mg/l (in water), 0 ... 100 % (in air), 0 ... 50 ºC / 32 ºF ... 122 ºF |
Resolution | 0.1 mg/l, 0.1 %, 0.1 ºC |
Accuracy | ±0.4 mg/l, ±0.7 %, ±0.8 ºC |
Calibration | In the air |
Temperature compensation | Automatic (0 ... 50 ºC / 32 ºF ... 122 ºF) |
Temperature measurement | |
Measurement range | 0 ... 60 ºC / 32 ºF ... 140 ºF |
Resolution | 0.1 ºC |
Accuracy | ±0.8 ºC |
Temperature compensation | Automatic (0 ... 60 ºC / 32 ºF ... 140 ºF) |
General specifications | |
Measurement rate | 1 second up to 8 hrs 59 mins 59 secs |
Display | LCD 52 x 38 mm / 2 x 1.5" |
Memory | SD card up to 16 GB (2 GB card included) |
Interface | RS-232 |
Software | Optional |
Power supply | 6 x 1.5 V AA batteries (optional power adapter) |
Operating conditions | 0 ... +50 ºC / < 85 % RH |
Dimensions | 177 x 68 x 45 mm / 7.0 x 2.7 x 1.8" |
Weight | 490 g / 1.1 lbs |
Price excl. VAT &. delivery
2 year Warranty
Price excl. VAT &. delivery
2 year Warranty
Calibration Solution pH10. pH electrodesdriftover time,causingmeasurement errors.Toensure high accuracy, we recommendregular calibration of pH meters.
Price excl. VAT &. delivery
2 year Warranty
Calibration Solution pH7. pH electrodesdriftover time,causingmeasurement errors.Toensure high accuracy, we recommendregular calibration of pH meters.
Price excl. VAT &. delivery
2 year Warranty
Calibration Solution pH4. pH electrodesdriftover time,causingmeasurement errors.Toensure high accuracy, we recommendregular calibration of pH meters.
Price excl. VAT &. delivery
2 year Warranty
Price excl. VAT &. delivery
2 year Warranty
Price excl. VAT &. delivery
2 year Warranty
Input voltage: 220 / 110 V AC, 50 / 60 Hz
Output voltage: DC 9 V
Output current: 1 A
Connector: Approx. Ø 2.5 mm, UK / European style plug
Price excl. VAT &. delivery
2 year Warranty
Price excl. VAT &. delivery
2 year Warranty
Electrolytic solution needed for the OD OXPB-11 sensor.
Price excl. VAT &. delivery
2 year Warranty
Replacement sensor OXHD-04 for the OXPB-11 oxygen electrode.
Price excl. VAT &. delivery
2 year Warranty
The BOX-LT1 carrying case offers protection when transporting and storing measuring devices and their accessories.
Price excl. VAT &. delivery
2 year Warranty
Electrode for measuring the redox potential (ORP) - Range: ±2000 mV - Electrode structure is silver-silver/chloride gel - Measuring temp from 0 to 100 °C (32 to 212 °F) - Body length 150 mm
Price excl. VAT &. delivery
2 year Warranty
Calibration Solution pH4, pH7 and pH10. pH electrodesdriftover time,causingmeasurement errors.Toensure high accuracy, we recommendregular calibration of pH meters.
-pH 4, pH 7 and pH 10
Price excl. VAT &. delivery
2 year Warranty
Price excl. VAT &. delivery
2 year Warranty
Input voltage: 110 V AC, 60 Hz
Output voltage: DC 9 V
Output current: 0.8 A
Connector: US / North American style plug
Price excl. VAT &. delivery
2 year Warranty
Price excl. VAT &. delivery
2 year Warranty
pH electrode especially for wine, beer and other liquids with low conductivity
Price excl. VAT &. delivery
2 year Warranty
Price excl. VAT &. delivery
2 year Warranty
Price excl. VAT &. delivery
2 year Warranty
Calibration solution 500 ml 111,8
mS / cm @ 25°C / 77°F
Potassium chloride 0.1 mol / l
DIN EN 27888
Price excl. VAT &. delivery
2 year Warranty
Price excl. VAT &. delivery
2 year Warranty
Price excl. VAT &. delivery
2 year Warranty
Price excl. VAT &. delivery
2 year Warranty
Price excl. VAT &. delivery
2 year Warranty
Price excl. VAT &. delivery
2 year Warranty
pH electrode especially for soil, mud and slurry
Price excl. VAT &. delivery
2 year Warranty
pH electrode especially for beer, blood and milk products
Price excl. VAT &. delivery
2 year Warranty
Price excl. VAT &. delivery
2 year Warranty
Calibration Solution pH4 and pH7. pH electrodes drift over time, causing measurement errors. To ensure high accuracy, we recommend regular calibration of pH meters.
Price excl. VAT &. delivery
2 year Warranty
Special pH probe:
Price excl. VAT &. delivery
2 year Warranty
Replacement pH-electrode (BNC-connector).