Description

Data logger with abs. air pressure sensor / measuring range -30 ... 60°C (-22 ... 140°F) / 
 instant data export via PDF and CSV / software / LC display / USB-A /
data memory for 13340 measuring points / optional with ISO calibration certificate 

The data logger has a measuring range of -30 ... 60°C / -22 ... 140°F and can be used in cold environments. In addition to temperature and humidity measurement, the data logger can also measure the absolute air pressure in the ambient atmosphere in a measuring range between 700 ... 1100 hpa. Due to the different sensors, the data logger already covers a wide range of measuring tasks. Typical applications of the data logger are, for example, the monitoring of refrigeration facilities, greenhouses or also in the monitoring of an office workplace. 

The measured values are stored on the internal memory of the data logger. The data logger has a memory capacity of 13340 measuring points. Once a measurement run has been completed, the stored measurement data can be read out from the data logger independently of the operating system. This is possible because the data logger is recognised as a mass data memory. When storing the measurement data, the measurement points are saved in a .pdf and in a .csv file.

With the corresponding software for the data logger, the measured values can be displayed graphically. In addition, settings for the data logger can be made via the software. For example, the storage interval can be set between 1 minute and 24 hours, visual alarm limits and start/stop pulses can be set for the data logger. Optionally, the data logger can be equipped with an ISO calibration certificate.

Highlights

- Temperature, relative humidity, air pressure
- Software for evaluating the measured data 
- Measuring range: -30 ... 60°C / -22 ... 140°F
- Data memory with 13340 measuring points 
- Data export immediately in PDF and CSV
- Optionally with ISO calibration certificate

Specification

Temperature  
Measuring range -30 ... 60°C / -22 ... 140°F
Resolution 0.1°C / °F
Accuracy ±1.0°C / 1.8°F bei -30 ... 0°C / -22 ... 32°F
  ±0.5°C / 0.9°F bei 0 ... 60°C / 32 ... 140°F
   
Relative humidity  
Measuring range 0 ... 100% r. F.
Resolution 0.1% r. F.
Accuracy ±5.0% r. F. bei 0 ... 20% r. F. und 80 ... 100% r. F.
  ±3.5% r. F. bei 20 ... 40% r. F. und 60 ... 80% r. F.
  ±3.0% r. F. bei 40 ... 60% r. F.
Absolute air pressure  
Measuring range 700 ... 1100 hpa
  525.0 ... 825.0 mmHg
  20.67 ... 32.48 inHg
Resolution 1 hpa
  0.1 mmHg
  0.01 inHg
Accuracy ±3 hpa
  ±2.5 mmHg
  ±0.1 inHg
   
Further specifications  
Memory 13340 measuring points
Data export .pdf, .csv
Storage rate 1 minute ... 24 hours
Interface USB-A
Power supply (USB-A)      5V DC, 0.1 A
Power supply (battery) 3V battery (CR2450)
Battery life Approx. 3 years
Display 1/4" LCD Display
Ambient conditions -30 ... 60°C / -22 ... 140°F, < 95% r. F., non-condensing
Dimensions 75 x 35 x 15 mm / 3 x 1.4 x 0.6 in
Weight 33 g / < 1 lb
   

Delivery Scope

1 x PCE-PDFL 10 data logger
1 x 3V button battery (CR2450) 
1 x Software CD
1 x Instruction manual