This innovative 3-in-1 Oscilloscope is the perfect combination of a powerful Oscilloscope, a versatile multimeter and a signal generator. It has been specially developed for electronics technicians, engineers and hobby users who are looking for a compact, versatile and user-friendly device to carry out their measurement tasks efficiently.
The 2-channel Oscilloscope offers a bandwidth of 10 MHz and a sampling rate of 50 MS/s, which enables signals to be reliably recorded and analysed. Whether troubleshooting circuits, observing waveforms or analysing transients, this Oscilloscope delivers clear and precise results. Thanks to its high resolution and simple operation, even complex signal curves can be easily visualised. The Oscilloscope image can be saved to the internal memory as a screenshot and transferred to a computer via the USB-C interface.
The device also has extensive multimeter functions that cover a wide range of measurements. These include voltage measurements (DC and AC voltage), current measurements (DC and AC current), resistance measurements, capacitance measurements and diode test. Another practical feature is the integrated non-contact voltage detection, which allows you to reliably detect live wires.
The signal generator ideally complements the device by generating signals within a range of 1 Hz to 2 MHz. It supports various signal shapes such as sine, square, triangle, half wave, full wave, noise and DC signals. This function makes the Oscilloscope particularly useful for tests, simulations and the development of circuits. Thanks to its compact design and the combination of Oscilloscope, multimeter and signal generator, this device is an indispensable tool for anyone who values efficiency and precision when working with electronics.
Direct voltage DC | |
Measurement range up to | 0 ... 9,999 V |
Resolution | 0,001 V |
Accuracy | ±0.5 % of Rd + 3 digits |
Direct voltage DC | |
Measurement range up to | 10 ... 99,99 V |
Resolution | 0,01 V |
Accuracy | ±0.5 % of Rd + 3 digits |
Direct voltage DC | |
Measurement range up to | 100 ... 999,9 V |
Resolution | 0,1 V |
Accuracy | ±0.5 % of Rd + 3 digits |
Direct current DC | |
Measurement range up to | 0 ... 9999 µA |
Resolution | 1 µA |
Accuracy | ±1.2 % of Rd + 3 digits |
Direct current DC | |
Measurement range up to | 10 ... 99,99 mA |
Resolution | 0,01 mA |
Accuracy | ±1.2 % of Rd + 3 digits |
Direct current DC | |
Measurement range up to | 100 ... 999,9 mA |
Resolution | 0,1 mA |
Accuracy | ±1.2 % of Rd + 3 digits |
Direct current DC | |
Measurement range up to | 1 ... 9,999 A |
Resolution | 0,001 A |
Accuracy | ±1.2 % of Rd + 3 digits |
Capacity | |
Measurement range up to | 0 ... 9,999 nF |
Resolution | 0,001 nF |
Accuracy | ±2 % of Rd + 5 digits |
Capacity | |
Measurement range up to | 10 ... 99,99 nF |
Resolution | 0,01 nF |
Accuracy | ±2 % of Rd + 5 digits |
Capacity | |
Measurement range up to | 100 ... 999,9 nF |
Resolution | 0,1 nF |
Accuracy | ±2 % of Rd + 5 digits |
Capacity | |
Measurement range up to | 1 ... 9,999 µF |
Resolution | 0,001 µF |
Accuracy | ±2 % of Rd + 5 digits |
Capacity | |
Measurement range up to | 10 ... 99,99 µF |
Resolution | 0,01 µF |
Accuracy | ±2 % of Rd + 5 digits |
Capacity | |
Measurement range up to | 100 ... 999,9 µF |
Resolution | 0,1 µF |
Accuracy | ±2 % of Rd + 5 digits |
Capacity | |
Measurement range up to | 1 ... 9,999 mF |
Resolution | 0,001 mF |
Accuracy | ±2 % of Rd + 20 digits |
Capacity | |
Measurement range up to | 10 ... 99,99 mF |
Resolution | 0,01 mF |
Accuracy | ±2 % of Rd + 20 digits |
AC voltage | |
Measurement range up to | 0 ... 9,999 V |
Resolution | 0,001 V |
Accuracy | ±1 % of Rd + 3 digits |
AC voltage | |
Measurement range up to | 10 ... 99,99 V |
Resolution | 0,01 V |
Accuracy | ±1 % of Rd + 3 digits |
AC voltage | |
Measurement range up to | 100 ... 750 V |
Resolution | 0,1 V |
Accuracy | ±1 % of Rd + 3 digits |
Alternating current AC | |
Measurement range up to | 0 ... 9999 µA |
Resolution | 1 µA |
Accuracy | ±1,5 % of Rd. + 3 digits |
Alternating current AC | |
Measurement range up to | 10 ... 99,99 mA |
Resolution | 0,01 mA |
Accuracy | ±1,5 % of Rd. + 3 digits |
Alternating current AC | |
Measurement range up to | 100 ... 999,9 mA |
Resolution | 0,1 mA |
Accuracy | ±1,5 % of Rd. + 3 digits |
Alternating current AC | |
Measurement range up to | 1 ... 9,999 A |
Resolution | 0,001 A |
Accuracy | ±1,5 % of Rd. + 3 digits |
Resistance | |
Measurement range up to | 0 ... 999,9 Ω |
Resolution | 0,1 Ω |
Accuracy | ±0.5 % of Rd + 3 digits |
Resistance | |
Measurement range up to | 1 ... 9,999 kΩ |
Resolution | 0,001 kΩ |
Accuracy | ±0.5 % of Rd + 3 digits |
Resistance | |
Measurement range up to | 10 ... 99,99 kΩ |
Resolution | 0,01 kΩ |
Accuracy | ±0.5 % of Rd + 3 digits |
Resistance | |
Measurement range up to | 100 ... 999,9 kΩ |
Resolution | 0,1 kΩ |
Accuracy | ±0.5 % of Rd + 3 digits |
Resistance | |
Measurement range up to | 1 ... 9,999 M Ω |
Resolution | 0,001 M Ω |
Accuracy | ±0.5 % of Rd + 3 digits |
Resistance | |
Measurement range up to | 10 ... 99,99 M Ω |
Resolution | 0,01 M Ω |
Accuracy | ±1,5 % of Rd. + 3 digits |
Temperature sensor | |
Measurement range up to | -55 ... +1300 °C |
Resolution | 0,1 °C |
Accuracy | ±2.5 % of Rd + 5 digits |
Oscilloscope specifications | |
Number of channels | 2 |
Bandwidth | 10 MHz |
Sampling rate | 50 MSa/s |
Memory depth | 32 kpts |
Input impedance | 10 M Ω |
Probe factors | 1-fold, 10-fold |
Max. input voltage | 400 V |
Vertical sensitivity | 20 mV/div - 10 V/div |
Function generator | |
Bandwidth | 1 ... 2000000 Hz |
Resolution | 1 Hz |
Channels | 1 |
Amplitude | 0.1 ... 3.3 Vpp |
Waveform length | 16 kpts |
Functions | Sine, Rectangle, Triangle, Half wave, Whole wave, Noise, DC |
General technical data | |
Measuring functions | Diode test, Continuity, non-contact voltage detection |
Display type | LC colour display |
Display size | 2,8 Inch |
Display resolution | 320x240 |
Storage medium | Internal memory |
Storage capacity | 8 MB |
Memory information | oscilloscope image saved as a BMP file |
Interface | USB-C, BNC |
Operating time | 6 h |
Automatic power-off from...to | 5 ... 30 min. |
Automatic power-off can be deactivated | Yes |
Safety standard | CAT III 1000V, CAT IV 600 V |
Fuse(s) | 10 A |
Trigger input | Mode: auto, normal, single Edge: rising, falling |
Menu language | English (GB), English, Portuguese, German, Russian, Japanese |
Protection class (device) | IP20 |
Power supply | 5 VDC / 1 A |
(Rechargeable) battery | 1 x 3,7 V internal , Lithium-ion polymer battery |
Capacity | 3000 mAh |
Operating conditions | 0 ... 50 °C , 0 ... 90 % RH |
Storage conditions | 0 ... 50 °C , 0 ... 90 % RH |
Dimensions ( L x W x H ) | 170 x 90 x 35 mm |
Weight | 300 g |