The Voltmeter is a versatile meter that is used in various areas of electrical engineering and electronics. The Voltmeter enables precise measurements of voltage, current and resistance and supports both direct and alternating parameters. It also offers practical functions such as checking electrical connections using continuity testing and testing diodes for functionality.
For specialised applications, the device offers additional functions such as capacitance and frequency measurement, temperature monitoring and non-contact voltage detection (NCV), which enables electrical fields and live wires to be reliably detected. The Voltmeter is equipped with overload protection, which prevents damage, particularly during high-current measurements, thanks to an integrated fuse. The meter is charged via a modern USB-C interface and it complies with the CAT III 1000 V and CAT IV 600 V safety standards, which ensures safe use even in demanding environments.
The device has three operating modes that can be easily switched via the menu. These modes are suitable for immediate measurements as well as for monitoring and recording maximum and minimum values with curve progression. The internal ring buffer for 8 measured values cannot be output via the interface. After setting threshold values, the multimeter can issue an alarm. The Voltmeter is therefore a reliable companion for professional users and hobby electronics engineers alike who require precise and versatile measurements.
Direct voltage DC | |
Measurement range up to | 0 ... 9,999 V |
Resolution | 0,001 V |
Accuracy | ±(0.5 % of Rd +3 digits) |
Direct voltage DC | |
Measurement range up to | 10 ... 99,99 V |
Resolution | 0,01 V |
Accuracy | ±(0.5 % of Rd +3 digits) |
Direct voltage DC | |
Measurement range up to | 100 ... 999,9 V |
Resolution | 0,1 V |
Accuracy | ±(0.5 % of Rd +3 digits) |
Direct current DC | |
Measurement range up to | 0 ... 9999 µA |
Resolution | 1 µA |
Accuracy | ±(1.2 % of Rd +3 digits) |
Direct current DC | |
Measurement range up to | 10 ... 99,99 mA |
Resolution | 0,01 mA |
Accuracy | ±(1.2 % of Rd +3 digits) |
Direct current DC | |
Measurement range up to | 100 ... 999,9 mA |
Resolution | 0,1 mA |
Accuracy | ±(1.2 % of Rd +3 digits) |
Direct current DC | |
Measurement range up to | 1 ... 9,999 A |
Resolution | 0,001 A |
Accuracy | ±(1.2 % of Rd +3 digits) |
Capacity | |
Measurement range up to | 0 ... 9,999 nF |
Resolution | 0,001 nF |
Accuracy | ±(2 % of Rd +5 digits) |
Capacity | |
Measurement range up to | 10 ... 99,99 nF |
Resolution | 0,01 nF |
Accuracy | ±(2 % of Rd +5 digits) |
Capacity | |
Measurement range up to | 100 ... 999,9 nF |
Resolution | 0,1 nF |
Accuracy | ±(2 % of Rd +5 digits) |
Capacity | |
Measurement range up to | 1 ... 9,999 µF |
Resolution | 0,001 µF |
Accuracy | ±(2 % of Rd +5 digits) |
Capacity | |
Measurement range up to | 10 ... 99,99 µF |
Resolution | 0,01 µF |
Accuracy | ±(2 % of Rd +5 digits) |
Capacity | |
Measurement range up to | 100 ... 999,9 µF |
Resolution | 0,1 µF |
Accuracy | ±(2 % of Rd +5 digits) |
Capacity | |
Measurement range up to | 1 ... 9,999 mF |
Resolution | 0,001 mF |
Accuracy | ±(5 % of Rd +20 digits) |
Capacity | |
Measurement range up to | 10 ... 99,99 mF |
Resolution | 0,01 mF |
Accuracy | ±(5 % of Rd +20 digits) |
AC voltage | |
Measurement range up to | 0 ... 9,999 V |
Resolution | 0,001 V |
Accuracy | ±(1 % of Rd +3 digits) |
AC voltage | |
Measurement range up to | 10 ... 99,99 V |
Resolution | 0,01 V |
Accuracy | ±(1 % of Rd +3 digits) |
AC voltage | |
Measurement range up to | 100 ... 750 V |
Resolution | 0,1 V |
Accuracy | ±(1 % of Rd +3 digits) |
Alternating current AC | |
Measurement range up to | 0 ... 9999 µA |
Resolution | 1 µA |
Accuracy | ±(1.5 % of Rd +3 digits) |
Alternating current AC | |
Measurement range up to | 10 ... 99,99 mA |
Resolution | 0,01 mA |
Accuracy | ±(1.5 % of Rd +3 digits) |
Alternating current AC | |
Measurement range up to | 100 ... 999,9 mA |
Resolution | 0,1 mA |
Accuracy | ±(1.5 % of Rd +3 digits) |
Alternating current AC | |
Measurement range up to | 1 ... 9,999 A |
Resolution | 0,001 A |
Accuracy | ±(1.5 % of Rd +3 digits) |
Resistance | |
Measurement range up to | 0 ... 999,9 Ω |
Resolution | 0,1 Ω |
Accuracy | ±(0.5 % of Rd +3 digits) |
Resistance | |
Measurement range up to | 1 ... 9,999 kΩ |
Resolution | 0,001 kΩ |
Accuracy | ±(0.5 % of Rd +3 digits) |
Resistance | |
Measurement range up to | 10 ... 99,99 kΩ |
Resolution | 0,01 kΩ |
Accuracy | ±(0.5 % of Rd +3 digits) |
Resistance | |
Measurement range up to | 100 ... 999,9 kΩ |
Resolution | 0,1 kΩ |
Accuracy | ±(0.5 % of Rd +3 digits) |
Resistance | |
Measurement range up to | 1 ... 9,999 mΩ |
Resolution | 0,001 mΩ |
Accuracy | ±(0.5 % of Rd +3 digits) |
Resistance | |
Measurement range up to | 10 ... 99,99 mΩ |
Resolution | 0,01 mΩ |
Accuracy | ±(1.5 % of Rd +3 digits) |
Frequency | |
Measurement range up to | 0 ... 9,999 Hz |
Resolution | 0,001 Hz |
Accuracy | ±(0.1 % of Rd +2 digits) |
Frequency | |
Measurement range up to | 10 ... 99,99 Hz |
Resolution | 0,01 FPM |
Accuracy | ±(0.1 % of Rd +2 digits) |
Frequency | |
Measurement range up to | 100 ... 999,99 Hz |
Resolution | 0,01 Hz |
Accuracy | ±(0.1 % of Rd +2 digits) |
Frequency | |
Measurement range up to | 1 ... 9,999 kHz |
Resolution | 0,001 kHz |
Accuracy | ±(0.1 % of Rd +2 digits) |
Frequency | |
Measurement range up to | 10 ... 99,99 kHz |
Resolution | 0,01 kHz |
Accuracy | ±(0.1 % of Rd +2 digits) |
Frequency | |
Measurement range up to | 100 ... 999,9 kHz |
Resolution | 0,1 kHz |
Accuracy | ±(0.1 % of Rd +2 digits) |
Frequency | |
Measurement range up to | 1 ... 9,999 MHz |
Resolution | 0,001 MHz |
Accuracy | ±(0.1 % of Rd +2 digits) |
Temperature sensor | |
Measurement range up to | -55 ... +1300 °C |
Resolution | 1 °C |
Accuracy | ±(2.5 % of Rd +5 digits) |
Temperature sensor | |
Measurement range up to | -67 ... +2372 °F |
Resolution | 1 °F |
Accuracy | ±(2.5 % of Rd +5 digits) |
General technical data | |
Measuring functions | HOLD, Continuity test, Diode test |
Display type | TFT colour display |
Display size | 2,4 Inch |
Display resolution | 240 x 320 |
Storage medium | Internal memory |
Storage capacity | 8 Values |
Safety standard | CAT III 1000V, CAT IV 600 V |
Fuse(s) | Low current range: 1 A fuse and high current range: 10 A fuse |
Measurement range selection | Automatic |
Display range | 9999 counts |
Menu language | English, Chinese, English (GB) |
Protection class (device) | IP20 |
Power supply | 5 V DC |
Capacity | 1500 mAh |
Operating conditions | 0 ... 40 °C , 0 ... 75 % RH |
Storage conditions | -20 ... 60 °C , 0 ... 80 % RH |
Dimensions ( L x W x H ) | 153 x 80 x 38 mm |
Weight | 191 g |