The three phase power data logger is a useful tool for precisely recording various electrical parameters. With a measuring range of 0 to 600 V for AC voltage and 0 to 1000 A for AC current, it offers sufficient flexibility for various applications. In addition to measuring active power, power factor, active energy and frequency, the three phase power data logger also allows you to monitor power consumption and the associated costs. With its compact dimensions of 220 x 195 x 105 mm, it is handy and easy to use.
The device's internal memory can store up to 2000 data records, which can be conveniently called up via the LC display. To transfer the data to a PC, however, it is necessary to install the supplied software, which enables both tabular and graphical visualisation of the data. The data can also be exported to a text document. Continuous data recording, which can be started via the three phase power data logger, takes place at intervals of one second until the memory is full. This memory can only be called up in the device. In addition, alarm functions can be set for upper and lower limit values for the measured power, AC voltage and AC current.
The integrated "cost function" allows the operator to set a cost factor to display the total cost of consumption. In addition, a weight factor can also be set to determine gas consumption, for example.
All in all, the three phase power data logger offers a wide range of applications and functionality for measuring and controlling electricity and energy consumption.
AC voltage AC | |
Measuring range | 0 ... 600 V |
Resolution | 0.1 V |
Accuracy | ±1 % v.Mw. ±5 digits |
Alternating current AC | |
Measuring range | 0 ... 1000 A |
Resolution | 0.1 A |
Accuracy | ±1.5 % v.Mw. ±5 digits (>10A) |
Effective performance | |
Measuring range | 0 ... 9999 kW |
Resolution | 0.01 kW |
Accuracy | ±2.5 % v.Mw. ±5 digits |
Power factor | |
Measurement range | 0.001 ... 1 |
Resolution | 0.001 |
Apparent power | |
Measuring range | 0 ... 9999 kVA |
Resolution | 0.01 kVA |
Accuracy | ±2.5% v.Mw. ±5 digits |
Effective energy | |
Measuring range | 0 ... 9999 kWh |
Resolution | 0.01 kWh |
Accuracy | ±2.5 % v.Mw. ±5 digits |
Frequency | |
Measuring range | 45 ... 65 Hz |
Resolution | 0.1 Hz |
Accuracy | ±0.5 % v.Mw. ±5 digits |
General technical data | |
Measurement functions | HOLD, MIN, MAX |
Display type | LCD with illumination |
Display size | 4.7 inch |
Storage medium | Internal memory |
Storage capacity | 2000 data records |
Storage interval of | 1 s |
Storage interval to | 1 s |
Interface | RS232 |
Standard(s) | EN 61010-1, EN 61326-1 |
Safety standard | CAT III 600 V |
Alarm | Acoustic, visual |
Alarm modes | Below, Above |
Measurement opening | Current clamp: max. 50 mm |
Menu language | English (US) |
Protection class (device) | IP30 |
Weight | 889 g |
Operating conditions | 0 ... 40 °C , 0 ... 80 % r.H |
Storage conditions | 0 ... 40 °C , 0 ... 80 % r.H |
Accumulator/battery | 6x 1.5 V AA battery , alkaline-manganese |
Capacity | 3000 mAh |
Dimensions ( L x W x H ) | 220 x 195 x 105 mm |