Defectoscope PCE-FD 20

Order no.: PCE-FD 20
GTIN (EAN): 4250348715234
4.598,90 €
5.472,69 €
price ex. (VAT / delivery)
:
4250348715234
PCE-FD 20
Delivery time: 1-2 working days

Description


PCE-FD 20 is a portable ultrasonic defectoscope with a large LCD screen that displays A-scan maps of ultrasonic signals as well as B-scan cross sections. Ideal for use in mechanical engineering, aerospace and metallurgical applications, this high-frequency ultrasound-based defectoscope uses a contact transducer (two different probes included; 45° and 90°) to measure material thickness and identify flaws and defects such as discontinuity in welds.

Highlights

- Operating frequency range: 1 ... 10 MHz
- Measured time interval range: 6 ... 1000 microseconds (µs)
- Sound velocity: 1000 ... 9999 m/s
- Implements shadow, echo and mirror-shadow testing methods
- Features a USB interface for downloading data to PC for detailed analysis
- Lightweight
- Battery or electric power
- 1.5 m long probe cable

Specification


Technical specifications

Operating frequency range

1 ... 10 MHz

Measure time interval range (scan duration)

6 ... 1000 microseconds (µs)

Sound velocity range

1000 ... 9999 m/s

Deviation of measurement of time intervals

Not exceed ± 0.025 µs

Max. deviation of amplitude of signals at receiver input in 0 ... 110 dB range

Not exceed ± 0.5 dB

Testing gain region

125 dB

Averaging over the quantity of starts

1 ... 16

Range of time-variable gain (TVG) / Number of control points TVG

40 dB / 15

Duration of excitation pulse to load

0 ... 0.5 µs

Amplitude of excitation pulse to 50 Ohm load, not less

100, 200, 300

Operating frequency range of receiver at -3 dB

1 ... 10 MHz

Deviation of amplitudes of input signals in 10 ... 100% range of screen height

Not more than 1 dB

Scanning

1 ... 1000 µs

Scanning delay

0 ... 2000 µs

Measurement range of time intervals

0 ... 1000 µs

Prism of probe delay

0 ... 15 µs

Automatic signaling of defects (AFS)

Dual-gate

Setting range of AFS gates

0 ... 2000 µs

Adjusting thresholds of AFS gates

0 ... 100%

Detection of signals (receiver)

Positive half-wave, radio mode

Dimensions of device (approx.)

80 x 162 x 35 mm / 3.14 x 6.37 x 1.37"

Dimensions display (approx.)

48 x 74 mm / 1.88 x 2.91"

Power supply

100 ... 250 V AC or 3 x 1.5 V AA batteries

Weight (approx.)

250 g / 0.55 lb (without batteries)



Delivery Scope

1 x PCE-FD 20 defectoscope
1 x probe cable (1.5 m long)
1 x contact transducer probe (90 °)
1 x contact transducer probe (45 °)
3 x 1.5 V batteries (AA)
1 x battery charger / electric power supply
1 x USB cable
1 x user manual