Environmental Tester PCE-VA 20-ICA incl. ISO Calibration Certificate
Combination anemometer-hygrometer-thermometer for assessing wind, weather, indoor / Outdoor environmental climate conditions
PCE-VA 20 is an environmental tester for assessing wind, weather, indoor / outdoor environmental climate conditions as well as for testing heating, ventilation and air conditioning or cooling (HVAC) systems. In addition to measuring air flow velocity (i.e., wind speed), this environmental tester measures volume flow, relative humidity (RH), air temperature, dew point temperature and wet-bulb temperature. This environmental tester features a 10 cm / 3.9" Ø fan impeller, easy-to-read backlit LCD, and functions such as display hold, average value, maximum value, minimum value, battery-saving automatic power off, low-battery indicator, and metric or imperial unit selection.
- Measures air flow velocity, volume flow, relative humidity, air temperature, dew point temperature and wet
bulb temperature
- Air flow velocity range: 0.2 ... 30 m/s (39.4 ... 5905.5 fpm)
- Accuracy: ±(1.5% of measured value + 0.3 m/s) when less than 20 m/s, ±(3% of measured value + 0.3
m/s) when more than 20 m/s
- Resolution: 0.1
- 10 cm / 3.9" Ø fan impeller
- Easy-to-read backlit LCD
- Display hold, average value, maximum value, minimum value, battery-saving automatic power off, low
battery indicator, and metric or imperial unit selection functions
- Incl. ISO Calibration Certificate
Technical Specification | ||
Air flow velocity measuring range |
|
|
Air flow velocity accuracy | <20 m/s: ±(1.5% of rdg. + 0.3 m/s) >20 m/s: ±(3% of rdg. + 0.3 m/s) |
|
Air temperature measuring range | -20 ... 60 °C / -4 ... 140 °F | |
Air temperature accuracy | ±0.6 °C | |
Air temperature resolution | 0.1 °C / °F | |
Humidity measuring range | 0.1 ... 99.9 % r.H. | |
Humidity accuracy | ±3 % r.H. (at 25 °C / 77 °F and 10...90 % r.H.) else: ±5 % r.H. |
|
Humidity resolution | 0.1 % r.H. | |
Temperature response time | 60 seconds | |
Humidity response time | 60 seconds | |
LCD update | 1 x per second | |
Wet bulb temperature display | -20 ... +59.9 °C / -4 ... 139.8°F | |
Dew point temperature display | -5 ... +59.9 °C / 23 ... 139.8°F | |
Volume flow display | 0 ... 99999 m³/min | |
Volume flow resolution | 0.1 m³/min (0...9999,9 m³/min) 1 m³/min (10000...99999 m³/min) |
|
Automatic shutdown | after 20 minutes of inactivity | |
LCD size | 32.5 x 54 mm / 1.28 x 2.13" (H x W) | |
Power supply | 4 x 1.5 V AAA batteries | |
Operating conditions | 0 ... +50 °C / 32 ... 89.6°F, <80 % r.H. | |
Storage conditions | -10 ... +50 °C / 14 ... 89.6°F, <90 % r.H. | |
Dimensions | 269 x 106 x 51 mm / 10.6 x 4.1 x 2.0" | |
Weight | ca. 200 g / 7 oz |
1 x Environmental Tester (PCE-VA 20)
4 x AAA batteries
1 x User manual
1 x Carrying case
1 x ISO Calibration Certificate
Calibration certificates are issued specifically for the customer and are excluded from the right of return.