Gas Leak Detector PCE-AQD 50A-ICA incl. ISO-Calibration Certificate

Order no.: PCE-AQD 50A-ICA
GTIN (EAN): 4250348736659
499,90 €
594,88 €
ISO Calibration
price ex. (VAT / delivery)
:
4250348736659
PCE-AQD 50A-ICA
Delivery time: 5-7 working days

Description

Gas Leak Detector with a battery life of up to 10 months / E-paper display / Easy operation / Data memory for 1 trillion measuring points / Measuring range up to 40,000 ppm CO2 /Temperature, humidity, atmospheric pressure, CO2

The Gas Leak Detector is specially designed for long-term monitoring of climatic conditions in, for example, offices, classrooms or lecture halls. The Gas Leak Detector has various sensors. Among other things, the Gas Leak Detector has a carbon dioxide sensor up to 40,000 ppm, a temperature sensor with a measuring range between 0 ... 50 °C, an ambient humidity sensor with a measuring range between 0 ... 100% RH and a barometer with a measuring range between 300 ... 2000 hPa. The Gas Leak Detector can therefore be used in many applications due to its large number of sensors. The measured values ​​are shown directly on the e-paper display of the air quality measuring device. A good / medium / bad rating of the carbon dioxide content in the ambient air is also displayed.

During the measurement, the Gas Leak Detector can automatically record the measured values. The measured values ​​are saved as .csv on the micro SD card. This means that the measurement data recorded by the Gas Leak Detector can be imported directly into the company's own database. The measurement data from the air quality measuring device can be displayed in graphical and tabular form via the software.

The Gas Leak Detector has an alarm function. This alarm mode can be used to set limit values ​​for the individual sensors. As soon as the set threshold value is reached in the Gas Leak Detector, this is indicated acoustically and visually via the alarm LED. After the Gas Leak Detector falls below the threshold value again, the alarm switches off again automatically.

The measured values ​​are displayed numerically on the 2.7" display of the Gas Leak Detector. For a better analysis of the last measured values, the display can be switched to a histogram display. The energy-saving e-paper display enables a long battery life for the Gas Leak Detector. Depending on the setting the battery can operate the Gas Leak Detector for about 10 months before it has to be recharged. In addition to the possible power supply via the built-in battery, the air quality measuring device can also be operated continuously via the micro USB charging cable.


Highlights

- Battery life of up to 10 months
- Measuring range up to 40,000 ppm CO2
- 32 GB data storage
- Temperature and humidity sensor
- .csv file format
- E-paper display with histogram display
- Display of atmospheric pressure
- Good / medium / bad rating
- Alarm limits
- Carbon dioxide and absolute pressure sensor
- incl. ISO-Calibration Certificate

Specification

CO² 
Measurement range up to  0 ... 40000 ppm
Resolution  1 ppm
Accuracy  ±(40 ppm +5 % of Rd) @ 400 ... 5000 ppm @ 25 ºC / 77 ºF
  
Relative humidity 
Measurement range up to  0 ... 80 % RH
Resolution  0,1 % RH
Accuracy  ±1.5 % RH
  
Relative humidity 
Measurement range up to  80 ... 100 % RH
Resolution  0,1 % RH
Accuracy  ±2 % RH
  
Air pressure 
Measurement range up to  300 ... 1250 hPa
Resolution  0,1 hPa
Accuracy  ±50 hPa @ -20 ... 75 ºC / 700 ... 1100 hPa
  
Temperature 
Measurement range up to  0 ... 50 °C
Resolution  0,1 °C
Accuracy  0.15
  
Temperature 
Measurement range up to  0 ... 20 °C
Resolution  0,1 °C
Accuracy  ±0.15 ºC
  
Temperature 
Measurement range up to  20 ... 50 °C
Resolution  0,1 °C
Accuracy  ±0.1 ºC
  
Temperature 
Measurement range up to  32 ... 60 °F
Resolution  0,1 °F
Accuracy  ±0.15 ºF
  
Temperature 
Measurement range up to  68 ... 122 °F
Resolution  0,1 °F
Accuracy  ±0.1 °F
  
General technical data 
Display type  E-paper
Display size  2,7 Inch
Storage medium  Micro SD card
Storage capacity  32 GB
Interface  USB-C
Operating time  10 Month(s)
Operating time additional information  10 months when measuring intervals are:
-temperature: 24 hours
-ambient humidity: 24 hours
-atmospheric pressure: 24 hours
-CO2: 24 hours
Alarm  optical, Acoustic
Menu language  English, Dutch, French, German, Italian, Polish, Spanish, Turkish
Protection class (device)  IP30
Power supply  5 V/1.5 A
Weight  280 g
Operating conditions  0 ... 50 °C , 0 ... 100 % RH
Storage conditions  -20 ... 60 °C , 0 ... 100 % RH
(Rechargeable) battery  1 x 7,4 V 18650 , Lithium-ion battery
Capacity  3400 mAh
Dimensions ( L x W x H )  130 x 90 x 40 mm

Delivery Scope

1 x Gas Leak Detector PCE-AQD 50A-ICA
1 x Micro USB charging cable
1 x 32 GB micro SD memory card including adapter
1 x Quick start guide
1 x ISO-Calibration Certificate