A illuminometer is used wherever a light check is necessary or recommended. The external light sensor of the illuminometer can be positioned according to requirements. The sensor cable has an extended length of approx. 1.5 metres. Different work or production projects require different lighting conditions. These lighting conditions can be created by using different light sources. Below you will find recommendations for lighting conditions in schools, factories or offices. Our illuminometer can show measured values on the display as soon as it is switched on. Various presettings can also be used to activate or deactivate the functions built into the device. These functions include the normal HOLD function, which freezes the measured value in the display. The extreme values and the average value can also be frozen in the display. Other functions of the illuminometer include zero adjustment, automatic switch-off and automatic range selection.
Measurements can be taken with the LED luxmeter in lux or food candle. The device is operated using just seven buttons, which enables one-handed operation. Our LED luxmeter is a battery-operated handheld device, making mobile measurements possible.
The external sensor of the illuminometer has a large exposure area. It is located on a coiled power cable, which reaches a length of around 1.5 metres when extended. There is a protective cap on the light sensor that protects the sensor from damage and wear. It should always be placed on the sensor if it is not to be used for a longer period of time. The protective cap is also required if a zero adjustment is to be carried out on the LED luxmeter.
Lighting intensity | |
Measuring range | 0 lx ... 40 lx |
Resolution | 0.01 lx |
Accuracy | ±3 % v.Mw. @ LED illuminant 2856 K, other visible light: ±6 % of the standard values |
Lighting intensity | |
Measuring range | 40 lx ... 400 lx |
Resolution | 0.1 lx |
Accuracy | ±3 % v.Mw. @ LED illuminant 2856 K, other visible light: ±6 % of the standard values |
Lighting intensity | |
Measuring range | 400 lx ... 4000 lx |
Resolution | 1 lx |
Accuracy | ±3 % v.Mw. @ LED illuminant 2856 K, other visible light: ±6 % of the standard values |
Lighting intensity | |
Measuring range | 4000 lx ... 40000 lx |
Resolution | 1 lx |
Accuracy | ±3 % v.Mw. @ LED illuminant 2856 K, other visible light: ±6 % of the standard values |
Lighting intensity | |
Measuring range | 40000 lx ... 400000 lx |
Resolution | 1 lx |
Accuracy | ±3 % v.Mw. @ LED illuminant 2856 K, other visible light: ±6 % of the standard values |
Lighting intensity | |
Measuring range | 0 fc ... 40 fc |
Resolution | 0.01 fc |
Accuracy | ±3 % v.Mw. @ LED illuminant 2856 K, other visible light: ±6 % of the standard values |
Lighting intensity | |
Measuring range | 40 fc ... 400 fc |
Resolution | 0.1 fc |
Accuracy | ±3 % v.Mw. @ LED illuminant 2856 K, other visible light: ±6 % of the standard values |
Lighting intensity | |
Measuring range | 400 fc ... 4000 fc |
Resolution | 1 fc |
Accuracy | ±3 % v.Mw. @ LED illuminant 2856 K, other visible light: ±6 % of the standard values |
Lighting intensity | |
Measuring range | 4000 fc ... 40000 fc |
Resolution | 1 fc |
Accuracy | ±3 % v.Mw. @ LED illuminant 2856 K, other visible light: ±6 % of the standard values |
General technical data | |
Measurement functions | MIN, MAX, HOLD, average value |
Units | lx, fc |
Display type | LCD |
Display size | 2.8 inch |
Measurement rate | 2.5 s |
Memory medium | Internal memory |
Memory capacity | 99 values |
Standard(s) | JIS C1609:1993, CNS 5519 |
Sensor | Silicone photodiode with built-in filter |
Automatic switch-off | 5 min |
Automatic switch-off can be deactivated | Yes |
Sensor length | 12 cm |
Light source | Measurable: White LED and any other visible light |
Reproducibility | ±3 % (with a standard incandescent light source at 2856 K and LED white light) ±6 % with other visible light sources |
Sensor cable length | 1.5 m |
Menu language | English (US) |
Protection class (device) | IP52 |
Weight | 311.5 g |
Dimensions (L x W x H) | 166 x 90 x 36 mm |
Operating conditions | 5 ... 40 °C , 0 ... 70 % r.H |
Storage conditions | -10 ... 60 °C , 0 ... 70 % r.H |
Accumulator/battery | 3x 1.5 V AA battery , alkaline-manganese |