The Gas Detector AQ-300 is a highly accurate instrument for measuring ozone concentrations in the air. The Gas Detector can be equipped with four different heads that vary in their measurement range. Furthermore, the Gas Detector has sensor heads for other gases available, which are automatically recognized when plugged into the device. Thus, you can use the Gas Detector in many different areas. The possibilities of the Gas Detector extend the use of ozone in your processes for bleaching oils, greases, wax, paper, synthetic fibers, cellulose or textiles,within the paper, textile, or lubricant production industries. Another field of application for the Gas Detector is in cleaning, disinfection and sterilisation of swimming pools, water treatment facilities or after fire damage or water damage. With a head for lower measurements of up to 0.150 ppm, you can measure ozone concentrations that have a negative effect on the mental state of humans.
Thanks to the leading GSS technology of the sensors, the Gas Detector not only is high precision, it also has a long lifespan. The unique possibility to refresh the sensors makes their maintenance more economical than the maintenance of other types of sensors. Depending on the model, the measured concentrations may be written to the internal memory of the Gas Detector via an analog interface with a 0... 5 V output, or the output is transferred via a USB interface to a PC. Similarly, a remote kit is available as an option, allowing the Gas Detector to take measurements in a secure room while the sensor is connected via cable to the Gas Detector. Through simplicity of operation the alarm thresholds for the optical or acoustic signal can be changed in a very short time. In addition to the measured concentrations in the LCD display, which are displayed in ppm or mg / m³, the high and low alarms are shown.
As Model 200 Series, in addition: | |||||
Alarm function | "High", "Low", Mute | ||||
Alarm output | Transistor output, 150-mA max | ||||
Low Alarm, High Alarm & Control | |||||
Analog output | 0... 5V | ||||
Location ID | Storage of the measuring location | ||||
Model 200, 300 and 500 Series | |||||
Power supply | 12V DC | ||||
Rechargeable battery | Lithium-Polymer 12V DC / 2700 mAh | ||||
Charger | 12.6V 2 A | ||||
Charging voltage | 12.6V | ||||
Charging time | 2... 3 hours | ||||
Lifecycle | > 500 charges | ||||
Housing | PC & ABS / IP20 & NEMA 1 | ||||
Dimensions (incl. opt. sensorsavailable) | 7.7 x 4.8 x 2.1 in / 195 x 122 x 54 mm | ||||
Weight | < 1 lb / 460 g (with battery) | ||||
Approvals | EN 50082-1: 1997, EN 50081-1: 1992, CE | ||||
Optional accessories for the gas detector: Sensors: | |||||
Gas Code | Meas. (ppm) | Min. (ppm) | Meas. (ppm) | Resolution. (ppm) | Temp. °C/ humidity. % |
GSS sensors (semiconductor sensors): | |||||
Ozone (O3) OZU | 0 ... 0.15 | 0.001 | < ±0.005 % | 0.001 | 0 ... +40 10 ... 90 |
Ozone (O3) OZL | 0 ... 0.5 | 0.001 | < ±0.008 0 ... 0.1 | 0.001 | 0 ... +40 10 ... 90 |
Ozone (O3) OZG | 0 ... 10 | 0.01 | < ±0.1 0...1 | 0.01 | 0 ... +40 10 ... 90 |
Hydrogen (H2) HA | 0 ... 5000 | 5 | < ±10 % | 1 | 0 ... +40 10 ... 90 |
Chlorine (CL2) ECL | 0 ... 10 | 0.1 | < ±10 % | 0.01 | 0 ... +40 10 ... 90 |
Ozone (O3) Leakage finder OZK | 0.01 | 0.01 | 0 ... +40 10 ... 90 | ||
Methane (CH4) MT | 0 ... 10,000 | 10 | < ±15 % | 1 | 0 ... +40 10 ... 90 |
NMHC VN | 0 ... 25 | 0.1 | < ±10 % 0.1 ... 25 | 0.1 | 0 ... +40 10 ... 90 |
Tetrachlorethylene (C2CL4) PE | 0 ... 200 | 1 | < ±5 0 ... 50 | 1 | 0 ... +40 10 ... 90 |
(VOC) VM | 0 ... 25 | 0.1 | ±10 % | 0.1 | 0 ... +40 10 ... 90 |
(VOC) VP | 0 ... 500 | 1 | ±10 % | 1 | 0 ... +40 10 ... 90 |
GSE sensors (electrochemical sensors): | |||||
Ammonia (NH3) ENG | 0 ... 100 | 0.2 | ±10 % | 0.1 | 0 ... +40 10 ... 90 |
Carbon monoxide (CO) ECN | 0 ... 100 | 0.1 | < ±1 0... 10 | 0.1 | 0 ... +40 10 ... 90 |
Carbon monoxide (CO) ECM | 0 ... 25 | 0.02 | < ±0.5 0 ... 5 | 0.01 | 0 ... +40 10 ... 90 |
Formaldehyde (CH2O) EF | 0 ... 10 | 0.01 | < ±0.05 0 ... 0.5 | 0.01 | 0 ... +40 10 ... 90 |
Sulfur- hydrogen (H2S) EHS | 0 ... 10 | 0.01 | < ±0.05 0 ...0.5 | 0.01 | 0 ... +40 10 ... 90 |
Sulfur- hydrogen (H2S) EHT | 0 ... 100 | 0.2 | < ±0.5 0 ... 5 | 0.1 | 0 ... +40 10 ... 90 |
Nitrogen dioxide (NO2) ENW | 0 ... 1 | 0.002 | < ±0.02 0 ... 0.1 | 0.001 | 0 ... +40 10 ... 90 |
Sulfur dioxide (SO2) ESO | 0 ... 10 | 0.01 | < ±0.05 0 ... 0.5 | 0.01 | 0 ... +40 10 ... 90 |
Sulfur dioxide (SO2) ESP | 0 ... 100 | 0.2 | < ±0.05 0 ... 0.5 | 0.1 | 0 ... +40 10 ... 90 |
NDIR sensors (infrared sensors): | |||||
Carbon dioxide (CO2) CD | 0 ... 2000 | 2 | < ±5 % (of the display) | 1 | 0 ... +40 10 ... 90 |
Carbon dioxide (CO2) CE | 0 ... 5000 | 5 | <± 5 % (of the display) | 1 | 0 ... +40 10 ... 90 |
Carbon dioxide (CO2) CF | 0 ... 5 % | 0.02 % | <± 5 % (of the display) | 0.01 % | 0 ... +40 10 ... 90 |
PID sensors (photoionization detector sensors): | |||||
VOC PDL | 0 ... 20 | 0.01 | < ±10 % | 0.01 | 0 ... +40 10 ... 90 |
VOC PDH | 0 ... 1000 | 0.2 | < ±10 % | 0.1 | 0 ... +40 10 ... 90 |
Combi sensors: | |||||
CO2 CO PID Code: MS2 | 0 ... 2000 0 ... 100 0 ... 25 | 2 0.1 0.01 | ±40 + 3 % ±10 % 1 ...100 ±10 % of result | 1 0.1 0.01 | 0 ... +40 10 ... 90 |
CO2 CO Code: MS1 | 0 ... 2000 0 ... 100 | 2 0.1 | ±40 + 3 % ±10 % 1 ...100 | 1 0.1 | 0 ... +40 10 ... 90 |
1 x Formaldehyde Tester AQ-300 Set EF
1 x 12V DC 800-mA AC/DC Power
Supply Unit
1 x Battery Pack 12V
1 x Operating
instructions