The hygrometer kit consists of the following devices:
- P1 / PCE-322A- PCE-322 A
The Noise
Meter PCE-322 A is particularly suitable for measurements
of sound nuisance in the field of industrial, health, safety and environment monitoring.
The noise
meter has a log function, which allows storage of up to 32,700 measurement values.
- Automatic range: 30 ... 130 dB
- Manual range: 30 ... 80 dB / 50 ... 100 dB / 80 ... 130 dB
- Resolution: 0.1 dB
- Accuracy: ±1.4 dB
- PCE-890U
The IR
Thermometer PCE-890 U has a
very good price / performance ratio. The IR thermometer is a professional device with
a measuring range up to +1150 ° C for contactless measurement of surface
temperatures. By the very good distance / spot ratio
of 50: 1,small objects can also be measured at a distance.
- Measuring range:
-50 ... +1150 °C
- High precision
- USB interface
- Adjustable emissivity
- PCE-174
The Light
Meter PCE-174 with a data memory for 16,000 readings is used to measure the lighting conditions in industry,
agriculture and research.
The
light
meter
is increasingly used also for
testing the lighting at workplaces, in
the decoration of shop windows and by designers.
- Range: 400.0 / 4000 / lux / 40.00 / 400.0 klux / 40.00 / 400.0 / 4000 / fc
/ 40.00 kfc
- Resolution.: 0.1 / 1 / 10 / 100 Lux / 0.01 / 0.1 / 1 / 10 FootCandle
- Accuracy: ±5 % of
range ±10 Digits (<10,000 Lux) / ±10 % of range ±10 Digits (>10,000
Lux)
- PCE-330
The Hygrometer PCE-330 is well suited for
the rapid measurement of room temperature and humidity. The precise hygrometer also allows the dew point (dew point temperature) to
be determined.
The hygrometer is equipped with a clear display and has a large memory (16000 values) to
save the readings.
- high precision
- large
memory (16,000 values)
- rapid measurement
Technical Specification | PCE-322A |
Noise levels | Low 30 ... 80 dB Medium 50 ... 100 dB High 80 ... 130 dB Auto 30 ... 130 dB |
Dynamic range | 50 dB |
Resolution | 0.1 dB |
Accuracy | ±1.4 dB |
Frequency | 31.5 Hz ... 8 kHz |
Storage capacity | 32700 values |
Frequency evaluation | A and C |
Time evaluation | fast (125 ms) slow (1 sec.) |
Technical Specification | PCE-890U |
Measuring range | -50 ... +1150 °C |
Accuracy | -50 ... 0 °C: ±4 °C 0 ...+500 °C: ±1.5 % / ±2 °C >500 °C: ±2 % / ±2 °C |
Resolution | < 1000 °C: 0.1 °C > 1000 °C: 1 °C |
Measuring spot | 50:1 |
Emission level | 0.1 ... 1 |
Spectral range | 8 ... 14 µm |
Technical Specification | PCE-174 |
Measuring range | 400.0 / 4000 / lux 40.00 / 400.0 klux 40.00 / 400.0 / 4000 / fc 40.00 kfc |
Resloution | 0.1 / 1 / 10 Lux 0.01 / 0.1 / 1 / 10 FootCandle |
Accuracy | ± 5% of reading ± 10 digits (<10,000 lux) ± 10% of reading ± 10 digits (<10,000 lux) |
Storage | 16,000 values |
Display update | 1.5 per second |
Technical Specification | PCE-330 |
Measuring range | |
Relative humidity | 0 ... 100% |
Temperature | -20 ... +60 °C |
Dew point temperature | -20 ... +60 °C |
Resolution | 0.1 °C / 0.1 % r.H. |
Accuracy (at 23 ° C) | < 10 % r.H. , > 90 % r.H.: ±4 % r.H. 10 % ... 90 % r.H.: ±3 % r.H. -20 °C ... +60 °C: ± 0,8 °C |
Sampling rate | 2 times per second |
Delivery PCE-322A |
1x Sound Level Meter PCE-322A, 1x Wind noise suppressor, 1x Interface cable, 1x Software, 1x Mini tripod, 1x Calibration screwdriver, 1x Battery, 1x Power adapter, 1x Carrying case, 1x User manual |
Delivery PCE-890U |
1x Digital Thermometer PCE-890U, 1x USB cable, 1x Software, 1x User manual |
Delivery PCE-174 |
1x Lux Meter PCE-174, 1x Light sensor, 1x Software, 1x USB cable, 1x Battery, 1x Device bag, 1x User manual |
Delivery PCE-330 |
1x Hygrometer PCE-330, 1x USB cable, 1x Software, 1x Battery, 1x User manual |