PCE-PDA A100L Manometer
Measuring instrument for barometric absolute pressure up to 200 kPa / Data logger / Graphic LCD / With USB interface / MAX MIN HOLD function
The manometer PCE-PDA A100L is suitable for the measurement of the atmospheric pressure. This manometer records the pressure from absolute zero to 200 kPa. The manometer can be used for many mobile applications in industry and crafts. This professional manometer can either be operated with batteries or rechargeable batteries. In battery mode, the USB interface allows charging of the inserted batteries. The PCE-PDA A100L manometer is equipped with a large LC display. A display illumination makes it easier to read the measured values even under poor conditions. The pressure is measured by an internally installed sensor.
A plug-in nipple is available from the pressure connection. At these, the pressure of air and liquids can be passed through quick couplings to the sensor. The manometer has a precision mode that allows the resolution of the measured value to be increased tenfold. In addition to the continuous pressure measurement, the display shows the maximum and minimum measured values directly in the display. At the touch of a button, this storage can be reset. Furthermore, the manometer performs a temperature measurement. To store the measured values for further documentation purposes, the manometer has a data logger. Here, the user can specify a storage interval and a recording period in which the pressure measured values are stored.
Measuring range pressure | 0 ... 200 kPa absolute |
Resolution | 0.01 kPa, 0.1 kPa |
Accuracy | <± 0.5% of the measuring range |
Nominal pressure | 200 kPa |
Overpressure | 200 kPa |
Burst pressure | 300 kPa |
Media | Liquids Air Non-aggressive gasses |
Measuring rate | 10 Hz |
Measurement units | Pa, hPa, kPa, MPa, mbar, bar, ATM, kg / cm², mmH2O, cmH2O, inH2O, mmHg, inHg, Torr, PSI, PSF |
Pressure | Absolute pressure |
Pressure connections | 5 mm nipple for quick connectors |
Max, Min and Hold function | Yes |
Data logger | 1024 memory slots 1 s ... 255 h Recording time per memory location 1 s ... 24h recording interval |
Medium | For air and non-explosive gasses |
Zero correction | Yes, with a zero key |
Averaging | Yes, between 0.1 ... 9.9 s |
Display | Graphic LCD with backlight |
Protection | IP41 |
Power supply | 2 x 1.5V AA battery / 1.2V NiMh battery 5V / 500-mA USB power adapter |
Current consumption | 50-mA (with backlight) 10-mA (without backlight) |
Operating temperature | 0 ... 50°C / 32 ... 122°F |
Storage temperature | 10 ... 55°C / 50 ... 131°F |
Dimensions | 145 x 85 x 35 mm / 5.7 x 3.3 x 1.4 in |